Fluke 5790B – AC Measurement Standard

The Fluke 5790B AC Measurement Standard is a precision instrument for calibrating AC voltage and current measurement devices. It provides highly accurate and stable AC signals, ensuring reliable calibration of multimeters, calibrators, and other test equipment. With exceptional accuracy and traceability, the 5790B is ideal for calibration laboratories and metrology institutes.

Model
Fluke 5790B
Calibration
Available on request
Price
$14,500
Status
In stock
RFQ ref
5790B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 5790B AC Measurement Standard is a precision calibration instrument that combines thermal transfer standard accuracy with digital multimeter usability. It performs absolute AC voltage and current measurements alongside AC/DC transfer mode operations for demanding metrology and calibration laboratory applications. A 6.5-inch color touchscreen displays measurement results, automated AC/DC or AC/AC difference calculations, and waveform analysis in real time.


Technical Specifications

AC Voltage Measurement

  • Range: 600 µV to 1000 V

  • Frequency: 10 Hz to 1 MHz (standard); 10 Hz to 30 MHz or 10 Hz to 50 MHz with wideband options

  • Absolute uncertainty: ± 24 ppm (one year, 23 °C ± 5 °C)

  • Wideband ranges: 2.2 mV to 7 V (Option /3); dedicated 50 MHz, 225 mV, 50 ohm input for RF power meter reference outputs AC Current Measurement

  • Direct, absolute, or relative current measurements with Fluke A40B Current Shunts

  • Shunt memory: Up to 150 shunts with serial numbers, calibration constants, and dates

  • Simultaneous voltage, current, and shunt information display Measurement Modes

  • Measurement mode: 8-digit resolution AC/DC voltmeter with internal DC reference

  • Transfer mode: AC/DC or external DC reference comparison; ± 24 ppm uncertainty

  • Simultaneous mA measurement and sourcing/simulation

  • Frequency measurement to 20 kHz

  • Peak-to-peak waveform and statistics functions

  • Waveform calculations for sine, square, triangle, and truncated waveforms

  • 5790A emulation mode for legacy system replacement


Key Features



  • 6.5-inch color touchscreen with real-time waveform display

  • Operating temperature range: 0 °C to 50 °C

  • Power: 95 VA nominal (120 VA with wideband option)

  • Line supply: 50/60 Hz; 100–120 V or 220–240 V AC

  • Dimensions: 43.2 cm (W) × 63 cm (D) × 17.8 cm (H) with rackmount kit

  • Weight: 24 kg (24.5 kg with wideband option)


Typical Applications Calibration and verification of AC voltage and current measurement devices in metrology laboratories, transfer standard operations, AC/DC difference measurements, and RF power meter reference output validation.

Specifications

ParameterValue
Frequency Range10 Hz to 1 MHz (standard)
50 MHz dedicated input | Voltage / Current Range600 µV to 1000 V (AC voltage)

Fluke 5790B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 5790B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 5790B price

This Fluke 5790B is listed at $14,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 5790B calibration cost

NIST-traceable calibration for the Fluke 5790B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →