Agilent/Keysight 6034A DC Power Supply, 60V/10A, 200 Watt

The Agilent/Keysight 6034A is a DC power supply, known for providing reliable and stable power for a variety of electronic testing and development applications. It features adjustable voltage and current settings, allowing users to tailor the power output to their specific needs. The 6034A includes built-in protection features to prevent damage from overloads or short circuits, ensuring the safety of both the power supply and the connected devices. Its solid design and precise control make it a valuable tool for engineers and technicians.

Model
Agilent / Keysight 6034A
Calibration
Available on request
Price
$590
Status
In stock
RFQ ref
6034A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 6034A is a 200 W autoranging DC power supply delivering 0–60 Vdc at 0–10 Adc for laboratory and system test applications. FET switching topology enables full power availability across the entire voltage–current operating envelope without manual range switching. The unIt has HP-IB (IEEE-488) programmability for voltage, current, and overvoltage protection settings, plus integrated measurement capability for closed-loop control and real-time monitoring of output conditions.


Technical Specifications



  • Output Range: 0–60 Vdc / 0–10 Adc (200 W maximum)

  • Programming Resolution: 15 mV voltage (12-bit); 2.5 mA current (12-bit)

  • Programming Accuracy (25 ±5°C): ±0.07% ±28 mV (CV mode); ±0.085% ±12.5 mA (CC mode)

  • Output Impedance: Typically 1 mΩ series with 30 µH; <1 Ω below 1 MHz

  • DC Output Isolation: ±240 Vdc from ground

  • Overvoltage Protection: Local range 1.7–64.5 V (0.2 V resolution); remote range 2.0–64.5 V (0.25 V resolution); ±0.7 V accuracy

  • AC Input: 104–127 Vac (standard)

  • Operating Environment: ≤95% RH, up to 2000 m altitude, indoor Category II, Pollution Degree 2

  • Cooling: Internal fan with thermal management


Key Features



  • Autoranging topology eliminates manual band switching for flexible voltage–current combinations

  • 12-bit programming resolution enables fine control across full output range

  • HP-IB interface supports remote voltage and current programming plus OVP adjustment

  • HP-IB measurement feedback allows real-time monitoring of actual output voltage and current

  • Programmable overvoltage protection with dual adjustment modes (local and remote)

  • Built-in overload and short-circuit protection

  • Service Request (SRQ) capability for fault notification


Typical Applications



  • Component and subsystem bench testing requiring stable 60 V/10 A output

  • Automated test systems with closed-loop voltage or current control

  • Development and validation of power-sensitive circuits and modules

  • Laboratory evaluation of loads across the full 200 W operating range


Compatibility & Integration HP-IB (IEEE-488) connectivity enables integration into instrumentation systems and ATE environments. Output impedance characteristics support both steady-state and dynamic load conditions with minimal ripple across standard test frequencies.

Specifications

ParameterValue
Voltage / Current Range0–10 A DC

Agilent / Keysight 6034A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 6034A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 6034A price

This Agilent / Keysight 6034A is listed at $590. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 6034A calibration cost

NIST-traceable calibration for the Agilent / Keysight 6034A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents