Fluke 6060A/AN – Synthesized Signal Generator

Fluke RF Signal Sources. Frequency range: 10 kHz to 520 MHz, Resolution: 10 Hz, Accuracy: 1 dB.

Model
Fluke 6060A/AN
Calibration
Available on request
Price
$850
Status
In stock
RFQ ref
6060A/AN
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 6060A/AN is a synthesized signal generator with integrated FM deviation meter, delivering precise RF signal generation and modulation measurement in a single instrument. Operating across 10 kHz to 520 MHz, it generates output levels from +13 dBm to -127 dBm with 10 Hz frequency resolution and 1 dB amplitude accuracy. The instrument supports AM and FM modulation with maximum FM deviation of 500 kHz, making it ideal for component characterization and on-channel radio validation.

Technical Specifications Signal Generation

Frequency range: 10 kHz to 520 MHz

Output amplitude: +13 dBm to -127 dBm

Output impedance: 50 ohms nominal

Frequency resolution: 10 Hz

Amplitude accuracy: 1 dB

SSB phase noise: -113 dBc/Hz at 20 kHz offset from 500 MHz carrier

Reverse power protection included Modulation

Modes: AM and FM

Maximum FM deviation: 500 kHz FM Deviation Meter

Input frequency range: 30 MHz to 500 MHz

Input signal level: 15 mV to 5 V rms

Measurement ranges: 500 kHz and 50.0 kHz full scale

Selectable polarity: ± peak

Modulation rate: 100 Hz to 8 kHz

Accuracy: ±6% of full-scale range (100 Hz to 8 kHz)

Key Features

Memory function for storing instrument settings

Interactive front panel with real-time operator feedback

IEEE-488 programmable remote control

Operating temperature: 0°C to 50°C (32°F to 122°F)

Standard full rack width form factor

Typical Applications

RF component and system testing (filters, amplifiers, mixers)

On-channel radio testing

Land-mobile, aviation, and tactical communication equipment validation

RF and electronics laboratory measurements

Compatibility & Integration IEEE-488 interface enables integration into automated test systems and remote operation from external controllers.

Specifications

ParameterValue
Frequency Range10 kHz to 520 MHz | Power Range (dBm): '+13 dBm to -127 dBm

Fluke 6060A/AN — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 6060A/AN. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 6060A/AN faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Fluke 6060A/AN price

This Fluke 6060A/AN is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 6060A/AN calibration cost

NIST-traceable calibration for the Fluke 6060A/AN is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents