HP / Agilent 6115A Voltage Source, 0-50V, 0.8A | 50-100V, 0.4A
The HP/Agilent 6115A is a versatile voltage source, delivering 0-50V at 0.8A or 50-100V at 0.4A. Ideal for a wide range of testing and research applications requiring stable and precise voltage control.
- Model
- HP / Agilent 6115A
- Calibration
- Available on request
- Price
- $239
- Status
- In stock
- RFQ ref
- 6115A
This unit
The HP/Agilent 6115A is a precision DC voltage source delivering 0–50V at 0–0.8A or 50–100V at 0–0.4A with automatic range crossover. Built for calibration, standards work, and laboratory power supply applications, it combines exceptional output accuracy with low drift and excellent load/line regulation. The instrument features a dual-function voltage/current meter, front-panel overvoltage protection via SCR crowbar, and optional remote programming capability via external voltage, resistance, or HP Multiprogrammer interface.
Technical Specifications Output Ratings
0–50V at 0–0.8A
50–100V at 0–0.4A
Automatic voltage range crossover above 50V when load current exceeds approximately 0.4A Accuracy & Stability
Output voltage accuracy: 0.025% (250 ppm) plus 1 mV
Meter accuracy: ±2% full scale (dual-function voltage/current meter)
Load regulation: 0.01% + 500 µA
Line regulation: 200 µA rms/1 mA p-p across rated line and load conditions
Thermal drift: 0.0015% + 200 µV (potentiometer-dependent; potentiometer wiper jump adds up to 10 mV)
Remote programming drift: 0.001% + 15 µV plus remote device stability Electrical Characteristics
DC output isolation: Floatable to 300V above ground
Overvoltage protection: SCR crowbar with front-panel-adjustable trip voltage (0.5V to 10% above rated output; minimum 2% + 0.5V margin)
Programming coefficient: 2000/V ± 0.01%
Constant current source operation supported Environmental & Physical
Operating temperature: 0–55°C
Storage temperature: −40 to +75°C
Cooling: Convection (no moving parts)
Dimensions: 197 mm W × 165 mm H × 337 mm D
Weight: 17 lbs (7.7 kg) net; 21 lbs (9.5 kg) shipping
Key Features
Dual-range output with automatic crossover for flexible test configurations
SCR crowbar overvoltage protection with user-adjustable trip threshold
Remote programming via external voltage, resistance, or HP Multiprogrammer
Constant current source capability
Single meter with integrated voltage and current measurement (±2% FS)
Convection-cooled design eliminates maintenance requirements
Typical Applications
Precision voltage calibration and working standards
System reference supplies
laboratory power applications
Parametric testing and component characterization
Compatibility & Integration Remote programming interfaces: HP Multiprogrammer, HP-IB Isolated D/A Power Supply Programmer, external voltage or resistance control. Optional ten-turn output current control (Option 008) and three-digit graduated decadial voltage control (Option 013) available.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0–0.4A, 0–0.8A |
HP / Agilent 6115A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 6115A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 6115A price
This HP / Agilent 6115A is listed at $239.2. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 6115A calibration cost
NIST-traceable calibration for the HP / Agilent 6115A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →