HP / Agilent 6115A Voltage Source, 0-50V, 0.8A | 50-100V, 0.4A

The HP/Agilent 6115A is a versatile voltage source, delivering 0-50V at 0.8A or 50-100V at 0.4A. Ideal for a wide range of testing and research applications requiring stable and precise voltage control.

Model
HP / Agilent 6115A
Calibration
Available on request
Price
$239
Status
In stock
RFQ ref
6115A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 6115A is a precision DC voltage source delivering 0–50V at 0–0.8A or 50–100V at 0–0.4A with automatic range crossover. Built for calibration, standards work, and laboratory power supply applications, it combines exceptional output accuracy with low drift and excellent load/line regulation. The instrument features a dual-function voltage/current meter, front-panel overvoltage protection via SCR crowbar, and optional remote programming capability via external voltage, resistance, or HP Multiprogrammer interface.

Technical Specifications Output Ratings

0–50V at 0–0.8A

50–100V at 0–0.4A

Automatic voltage range crossover above 50V when load current exceeds approximately 0.4A Accuracy & Stability

Output voltage accuracy: 0.025% (250 ppm) plus 1 mV

Meter accuracy: ±2% full scale (dual-function voltage/current meter)

Load regulation: 0.01% + 500 µA

Line regulation: 200 µA rms/1 mA p-p across rated line and load conditions

Thermal drift: 0.0015% + 200 µV (potentiometer-dependent; potentiometer wiper jump adds up to 10 mV)

Remote programming drift: 0.001% + 15 µV plus remote device stability Electrical Characteristics

DC output isolation: Floatable to 300V above ground

Overvoltage protection: SCR crowbar with front-panel-adjustable trip voltage (0.5V to 10% above rated output; minimum 2% + 0.5V margin)

Programming coefficient: 2000/V ± 0.01%

Constant current source operation supported Environmental & Physical

Operating temperature: 0–55°C

Storage temperature: −40 to +75°C

Cooling: Convection (no moving parts)

Dimensions: 197 mm W × 165 mm H × 337 mm D

Weight: 17 lbs (7.7 kg) net; 21 lbs (9.5 kg) shipping

Key Features

Dual-range output with automatic crossover for flexible test configurations

SCR crowbar overvoltage protection with user-adjustable trip threshold

Remote programming via external voltage, resistance, or HP Multiprogrammer

Constant current source capability

Single meter with integrated voltage and current measurement (±2% FS)

Convection-cooled design eliminates maintenance requirements

Typical Applications

Precision voltage calibration and working standards

System reference supplies

laboratory power applications

Parametric testing and component characterization

Compatibility & Integration Remote programming interfaces: HP Multiprogrammer, HP-IB Isolated D/A Power Supply Programmer, external voltage or resistance control. Optional ten-turn output current control (Option 008) and three-digit graduated decadial voltage control (Option 013) available.

Specifications

ParameterValue
Voltage / Current Range0–0.4A, 0–0.8A

HP / Agilent 6115A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 6115A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

HP / Agilent 6115A price

This HP / Agilent 6115A is listed at $239.2. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 6115A calibration cost

NIST-traceable calibration for the HP / Agilent 6115A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents