The Agilent/Keysight 6575A is a 2 kW programmable DC power supply engineered for precision test, design validation, and manufacturing environments. It delivers 0–120 V and 0–18 A with exceptionally low noise and fast transient recovery, supporting both front-panel and analog programming modes alongside remote sensing and parallel/series operation for extended capability.


Technical Specifications

Output Ratings

  • Voltage: 0 to 120 V

  • Current: 0 to 18 A

  • Maximum Power: 2000 W at 40°C Programming Accuracy (25°C ±5°C)

  • Voltage: 0.04% + 120 mV

  • Current: 0.1% + 12 mA Ripple and Noise (20 Hz to 20 MHz)

  • Voltage RMS: 1.9 mV

  • Voltage Peak-to-Peak: 16 mV

  • Current RMS: 12 mA Line and Load Regulation

  • Voltage: 0.002% + 300 µV Transient Response

  • Recovery: <900 µs for 100 mV excursion on 100%–50% or 50%–100% load step

  • Full-load programming: 30–195 ms (10% to 90% rise/fall with resistive load) Operating Temperature: 0 to 55°C


Key Features



  • Front-panel and analog programming control

  • Remote sensing supports ±50% rated output voltage drop per load lead

  • Auto-parallel and series operation modes

  • Overvoltage and overcurrent protection with CV/CC mode crossover

  • Fast programmable up/down control with noise-optimized fan speed management

  • UL Listed and CSA Certified; Safety Class 1 with protective earth terminal

  • Benchtop and rack-mountable configurations


Typical Applications Electronic design and prototype testing, component qualification, manufacturing test stations, and research environments demanding stable, precise DC power with minimal ripple and rapid load-transient settling.

Specifications

ParameterValue
Voltage / Current Range0–120 V, 0–18 A

Agilent / Keysight 6575A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 6575A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 6575A price

This Agilent / Keysight 6575A is listed at $750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 6575A calibration cost

NIST-traceable calibration for the Agilent / Keysight 6575A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →