Baker Hughes / Panametrics 703-1250 Controller Board

The Baker Hughes / Panametrics 703-1250 is a controller board designed for industrial applications. It provides reliable control and monitoring functions, ensuring optimal performance and efficiency in various industrial processes.

Model
Baker Hughes / Panametrics 703-1250
Calibration
Available on request
Price
$950
Status
In stock
RFQ ref
703-1250
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Baker Hughes / Panametrics 703-1250 Controller Board is the central processing unit for the Moisture Image Series 1 analyzer, delivering real-time measurement and control across one to six independent channels. This controller board integrates moisture and oxygen analysis in liquids and gases with simultaneous monitoring of pressure, temperature, and auxiliary sensor inputs, making it suitable for demanding industrial process control applications.

Technical Specifications

Measurement Channels: 1 to 6 simultaneous channels

Moisture Resolution: 16-bit

Measurement Parameters: Moisture in liquids and gases; oxygen concentration in gases; pressure; temperature; auxiliary inputs (0/4–20 mA or 0–4 V sources)

Display: Large backlit LCD with matrix and line-graph visualization formats

Probe Compatibility: MISP, TF, and M Series type moisture probes

Probe Cable Distance: Up to 915 m (3000 feet) using 22 AWG twisted pair cable

Terminal Connections: M3 screw terminals on terminal board; 0.5 N·m tightening torque; accepts stripped and crimped conductors

Cabling Requirements: Copper conductors with 60/75 °C insulation; twisted and shielded cables recommended for non-power connections; individual cable gauges and lengths per connection type (0.35–1 mm², 3–5 m compensated lengths)

Key Features

Windows-compatible software interface (PanaView) supports PC-based data logging, retrieval, archiving, and real-time trending

Multiple communication protocols: PanaLink and IDM protocols

Instrument interfaces via RS232, RS485, TCP/IP, IrDA, and IR232

Menu-driven function keys with point-and-click graphical control

Real-time data visualization and historical graph generation

Compatibility & Integration

PanaView software compatible with Windows 98 SE, NT 4.0 SP 6+, ME, 2000, and XP

Minimum PC requirements: 64 MB RAM, 300 MHz Pentium CPU; Internet Explorer 5.0 or higher recommended

Oxygen cell ranges: 0–1/10/100 ppmv or 0–0.5/5/50 ppmv with cable distances up to 90 m

Baker Hughes / Panametrics 703-1250 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Baker Hughes / Panametrics 703-1250. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Baker Hughes / Panametrics 703-1250 faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

Baker Hughes / Panametrics 703-1250 price

This Baker Hughes / Panametrics 703-1250 is listed at $950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Baker Hughes / Panametrics 703-1250 calibration cost

NIST-traceable calibration for the Baker Hughes / Panametrics 703-1250 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →