Fluke 80i-1000s AC Current Probe for Oscilloscopes
The Fluke 80I-1000S is an AC current probe designed to extend the current measuring capabilities of oscilloscopes. It is capable of measuring AC current up to 1000 A peak. The probe is compatible with most oscilloscopes, multimeters, or other voltage measuring instruments that have a BNC input.
- Model
- Fluke 80I-1000S
- Calibration
- Available on request
- Price
- $227
- Status
- In stock
- RFQ ref
- 80I-1000S
This unit
The Fluke 80i-1000s is an AC current probe that extends the current measurement capabilities of oscilloscopes and other voltage-measuring instruments through non-intrusive clamp-on measurement. It measures AC current from 100 mA to 1000 A rms continuously, with instantaneous peak capability to 2000 A, making it suitable for industrial and power environments where accurate distorted waveforms and harmonics characterization is required.
Technical Specifications Current Measurement
Continuous range: 100 mA to 1000 A rms
Instantaneous peak: 2000 A
Switch-selectable ranges: 10 A, 100 A, 1000 A Frequency Response
Operating range: 5 Hz to 100 kHz
Built-in 100 kHz low-pass output filter eliminates wideband noise Output Signal
Maximum output: 2 V peak
Three switch-selectable sensitivities: 1 mV/A (up to 1000 A peak), 10 mV/A (up to 200 A peak), 100 mV/A (up to 20 A peak) Accuracy
100 mA to 10 A: 3% of reading ± 100 mA
0.5 A to 100 A: 2% of reading
5 A to 1000 A: 2% of reading
Specifications valid 45 Hz to 1 kHz at 23 °C ± 5 °C, 20–75% relative humidity, centered conductor, no DC component, <40 A/m external magnetic field Mechanical
Maximum conductor diameter: 54 mm (2.13 inches)
Dimensions: 111 mm × 216 mm × 45 mm
Weight: 550 g (1.21 lbs)
IP 40 enclosure protection; 1 meter drop test per IEC 68-2-32; 100 G mechanical shock per IEC 68-2-27
Key Features
Double or reinforced insulation throughout, Protection Class II per UL 3111, ANSI/ISA-S82.01-1994, CAN/CSA C22.2 No. 1010.1-92, IEC 1010-1, and EN 61010-1
CAT III 600 V rated: 600 V AC rms working voltage and 600 V AC rms float voltage
Built-in passive filter suppresses noise and ring on rapidly rising di/dt waveforms
Insulated BNC output connector with 1.6 m PVC-insulated coaxial cable
Compatibility & Integration Works with any oscilloscope accepting standard BNC connectors and input impedance ≥1 MΩ in parallel with a capacitive load.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 5 Hz to 100 kHz | Voltage / Current Range: 100 mA to 1000 A rms continuous |
Fluke 80I-1000S — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 80I-1000S. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke 80I-1000S price
This Fluke 80I-1000S is listed at $227. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 80I-1000S calibration cost
NIST-traceable calibration for the Fluke 80I-1000S is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →