Agilent / Keysight 8349B Microwave Amplifier, 2 to 20 GHz

Agilent / Keysight RF Amplifiers. Frequency Range: 2 to 20 GHz, Power Range (dBm): +20 dBm (100 mW) output (2–18.6 GHz unleveled); +18 dBm (63 mW) output (18.6–20 GHz unleveled); +27 dBm maximum continuous input, Voltage / Current Range: 100, 120, 220, 48–66 Hz, or 240 VAC.

Model
Agilent / Keysight 8349B
Calibration
Available on request
Price
$626
Status
In stock
RFQ ref
8349B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 8349B is a broadband microwave power amplifier delivering 2 to 20 GHz signal amplification for test, measurement, and signal generation applications. Designed for communications, radar, and electronic warfare systems, the 8349B provides consistent gain and output power across its operating range with selectable leveled and unleveled output modes.


Technical Specifications

Frequency Range: 2 to 20 GHz Gain

  • 2.0 to 18.6 GHz: ≥15 dB minimum small signal gain (at –5 dBm input)

  • 18.6 to 20.0 GHz: ≥13 dB minimum small signal gain

  • Typical: 22 dB Output Power (at +5 dBm input)

  • 2.0 to 18.6 GHz leveled: +19 dBm (80 mW) minimum

  • 2.0 to 18.6 GHz unleveled: +20 dBm (100 mW) minimum

  • 18.6 to 20.0 GHz leveled: +17 dBm (50 mW) minimum

  • 18.6 to 20.0 GHz unleveled: +18 dBm (63 mW) minimum

  • 1 dB compression point: +21 dBm nominal Power Flatness (Leveled): ±1.25 dB Noise Figure: 8.5 dB typical Impedance: 50 Ω nominal (input and output) VSWR

  • Input leveled: ≤2.8

  • Output leveled: ≤2.5

  • Output unleveled: ≤4.8 (2.0–5.0 GHz) to ≤3.2 (11.0–20.0 GHz) Spectral Purity

  • Harmonics: <–20 dBc (2.0–11.0 GHz); 50 dB typical Pulse Performance: Rise/fall time <10 ns typical; delay <8 ns typical Maximum Continuous Input: +27 dBm RF


Key Features



  • Dual-mode operation: leveled output for dynamic range enhancement; unleveled for maximum power

  • Precision Type-N female connectors (input and output)

  • Fast pulse response supporting <10 ns rise/fall times

  • High reverse isolation enabling use in bidirectional test setups

  • AC power: 100, 120, 220, or 240 VAC, 48–66 Hz


Physical



  • Dimensions: 133 mm (H) × 214 mm (W) × 366 mm (D)

  • Weight: 7.3 kg (16 lbs) net


Typical Applications



  • Network analyzer drive and receiver amplification

  • Microwave power generation for radar and EW signal sources

  • Low-noise preamplification in receiver chains

  • High-power signal conditioning across X-, Ku-, and K-band frequencies

Specifications

ParameterValue
Frequency Range2 to 20 GHz | Power Range (dBm): '+26 dBm maximum input
+17 dBm to +18 dBm output (18.6–20.0 GHz) | Voltage / Current Range100, 120, 200, or 240 V (±10%)

Agilent / Keysight 8349B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 8349B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 8349B price

This Agilent / Keysight 8349B is listed at $626.38. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 8349B calibration cost

NIST-traceable calibration for the Agilent / Keysight 8349B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents