Agilent / Keysight 85422E Receiver RF Section, 9 kHz to 2.9 GHz

The Agilent/Keysight 85422E is a receiver RF section, designed to operate within a frequency range of 9 kHz to 2.9 GHz. It is a component of the 8542E spectrum analyzer system.

Model
Agilent / Keysight 85422E
Calibration
Available on request
Price
$4,678
Status
In stock
RFQ ref
85422E
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 85422E Receiver RF Section is the RF front-end component of the 8542E EMI test receiver system, delivering precise signal reception and analysis across 9 kHz to 2.9 GHz. This modular unit captures and processes RF signals for EMI and conformance testing, with compliance to CISPR 16-1 and industry standards including CISPR, EN, FCC, VCCI, and VDE. It operates standalone for pre-compliance testing and integrates with the 85420E RF Filter Section to form a complete EMI compliance receiver.


Technical Specifications

Frequency Performance

  • Operating range: 9 kHz to 2.9 GHz

  • Tuning modes: Manual, stepped, and scanning (linear or logarithmic)

  • Frequency reference aging: < ±1 × 10⁻⁷/year

  • Frequency reference settability: < ±1 × 10⁻⁸

  • Temperature stability: 10 MHz Detection & Measurement

  • Measurement detectors: Peak, Quasi-Peak, and Average

  • IF bandwidths (6 dB): 200 Hz, 9 kHz, 120 kHz (CISPR 16-compliant)

  • Diagnostic IF bandwidths (3 dB): 30 Hz to 3 MHz in 1-3-10 steps, and 5 MHz

  • Averaging bandwidths: 30 Hz to 3 MHz in 1-3-10 steps with digital filters (1, 3, 10 Hz)

  • Sweep time: 20 ms to 100 sec

  • Sweep triggers: Free Run, Single, Line, Video, External Input Characteristics

  • Input connector: Type-N female, 9 kHz to 2.9 GHz

  • Preamplification gain: 27 dB

  • Input attenuator range: 0 to 70 dB

  • Input VSWR: 2:1 (0 dB attenuation); 1.2:1 (10 dB attenuation); 1.6:1 (> 1.5 GHz, 10 dB attenuation)

  • Maximum safe input (average power): 137 dBµV (30 dBm)

  • Maximum safe input (peak pulse): 100 W peak for 10 µsec at 1% duty cycle with 30 dB attenuation

  • DC voltage rating: 0 V (DC coupled); 50 V (AC coupled) Counter Resolution

  • Spans ≤ 10 MHz: Selectable from 10 Hz to 100 kHz

  • Spans > 10 MHz: Selectable from 100 Hz to 100 kHz


Key Features



  • IF overload protection with dedicated detectors

  • Quasi-Peak time constants conforming to CISPR Publication 16

  • Modular architecture for integration into complex test setups

  • Three measurement detector types for standards compliance testing


Typical Applications



  • EMI/RFI pre-compliance and conformance testing

  • Radiated and conducted emissions measurement

  • RF signal monitoring and analysis

  • Systems integration for automated compliance receivers


Compatibility & Integration The 85422E pairs with the 85420E RF Filter Section to form a complete EMI compliance receiver meeting CISPR 16-1 requirements. Standalone operation is supported for pre-compliance applications.

Specifications

ParameterValue
Frequency Range9 kHz to 2.9 GHz | Power Range (dBm): 30 dBm maximum average power input | Voltage / Current Range: 50 V (AC coupled), DC: 0 V (DC coupled)

Agilent / Keysight 85422E — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 85422E. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight 85422E price

This Agilent / Keysight 85422E is listed at $4,678. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 85422E calibration cost

NIST-traceable calibration for the Agilent / Keysight 85422E is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →