Agilent / Keysight 85518A 4-in-1 OSLT Mechanical Calibration Kit, DC to 18 GHz, Type-N (m) 50 ohm
Agilent / Keysight RF Calibration Equipment. Frequency Range: DC to 18 GHz.
- Model
- Agilent / Keysight 85518A
- Calibration
- Available on request
- Price
- $4,824
- Status
- In stock
- RFQ ref
- 85518A
This unit
The Agilent/Keysight 85518A is a 4-in-1 OSLT mechanical calibration kit designed for precision network analyzer calibration across DC to 18 GHz. It has open, short, load, and thru standards with Type-N male connectors and 50 ohm impedance, enabling accurate error correction and characterized measurements in RF and microwave test environments.
Technical Specifications
- Frequency Range: DC to 18 GHz
- Connector Type: Type-N male, 50 ohm
- Calibration Standards: Open, Short, Load, Thru (4-in-1)
- Physical Dimensions: 106 × 72 × 22 mm (H × W × D)
- Weight: Approximately 2 lbs
- Operating Temperature: +18 °C to +28 °C
- Storage Temperature: −40 °C to +70 °C Open Phase Error:
- 0–6 GHz: ≤ 2.0°
- 6–9 GHz: ≤ 3.0°
- 9–18 GHz: ≤ 4.0° Short Phase Error:
- 0–6 GHz: ≤ 1.5°
- 6–9 GHz: ≤ 2.5°
- 9–18 GHz: ≤ 3.0° Load Return Loss:
- 0–6 GHz: ≥ 42 dB
- 6–9 GHz: ≥ 35 dB
- 9–18 GHz: ≥ 32 dB Through Return Loss (typical):
- DC–4 GHz: ≥ 38 dB
- 4–8 GHz: ≥ 34 dB
- 8–18 GHz: ≥ 28 dB Through Electrical Delay: 245.383 ps (male-male)
Through Insertion Loss (typical): ≤ 0.035 dB × √(f/GHz) (DC to 18 GHz, male-male)
Offset Delay (Open, male): 85.954 ps
Key Features
- Compact, lightweight design for laboratory and field deployment
- Integrated thru standard enables calibration of non-insertable devices such as cables and filters with male-male connectors
- All four OSLT standards included for complete error correction
- Type-N male connectors ensure compatibility with standard RF and microwave equipment
- Protective storage recommended to maintain precision performance and connector integrity
Typical Applications
- Network analyzer calibration and error correction
- RF and microwave measurement verification
- Cable and filter device characterization
- Precision test system validation across DC to 18 GHz
Compatibility & Integration The 85518A interfaces with Agilent/Keysight network analyzers and compatible third-party RF instrumentation equipped with Type-N male connectors. The male-male thru configuration supports direct connection to test ports and external devices without adapter requirements.
Agilent / Keysight 85518A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 85518A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight 85518A price
This Agilent / Keysight 85518A is listed at $4,823.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 85518A calibration cost
NIST-traceable calibration for the Agilent / Keysight 85518A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →