Agilent / Keysight 8562A 9 kHz 22 GHz spectrum analyzer

Agilent / Keysight Spectrum Analyzers. Frequency Range: 9 kHz to 22 GHz (26.5 GHz with Option 026); up to 325 GHz with external mixers, Power Range (dBm): -120 dBm to +30 dBm.

Model
HP 8562A
Calibration
Available on request
Price
$2,084
RFQ ref
8562A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 8562A is a portable spectrum analyzer delivering drift-free RF and microwave signal analysis from 9 kHz to 22 GHz. Synthesized tuning and MIL-T-28800C ruggedization enable reliable field deployment. The instrument combines wide frequency coverage with precision measurement across demanding test environments, supporting external mixing to 325 GHz and optional extension to 26.5 GHz.


Technical Specifications

Frequency Performance

  • Frequency range: 9 kHz to 22 GHz (26.5 GHz with Option 026)

  • External mixer capability: Up to 110 GHz (HP 11970 Series); up to 325 GHz (commercial mixers)

  • Preselection: Standard from 2.75 GHz to 22 GHz

  • Frequency span: 0 Hz to 2.5 kHz × N

  • Frequency readout accuracy: ±(frequency readout × reference accuracy + 5% × span + 15% × RBW + 10 Hz)

  • Frequency reference accuracy: <4 × 10⁻⁶/yr (standard); <0.13 × 10⁻⁶/yr (Option 003) Resolution & Selectivity

  • Resolution bandwidth: 100 Hz to 1 MHz (1, 3, 10 sequence) and 2 MHz, with accuracy ±30% (100 Hz) to ±25% (1–2 MHz)

  • Selectivity: 10 dB attenuation); +50 dBm peak pulse (<10 µs, 2.75 GHz)


Key Features



  • Synthesized tuning delivers drift-free frequency accuracy

  • Field-ready design meets MIL-T-28800C specifications

  • Low noise floor supports detection of weak signals across the microwave spectrum

  • Flexible RBW and VBW settings optimize measurement resolution and trace smoothing

  • Attenuator switching accuracy <±0.6 dB/10 dB step below 2.9 GHz


Typical Applications



  • RF and microwave system troubleshooting

  • Signal characterization in test and integration environments

  • Spectrum monitoring and interference analysis

  • Component and subsystem validation


Compatibility & Integration Supports external mixers for extended frequency coverage and integrates with standard RF measurement workflows.

Specifications

ParameterValue
Frequency Range1 kHz to 22 GHz (Option 026: to 26.5 GHz
external mixersto 325 GHz) | Power Range (dBm): '-120 dBm to +30 dBm reference level
+50 dBm peak pulse input | Voltage / Current Range1.8 A max, 115 VAC: 90-140 V RMS, 3.2 A max
230 VAC180-250 V RMS

HP 8562A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP 8562A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

HP 8562A price

This HP 8562A is listed at $2,084.38. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP 8562A calibration cost

NIST-traceable calibration for the HP 8562A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →