Ametek / EG&G / Princeton Applied Research AM-1 Input Transformer
The Ametek/EG&G/Princeton Applied Research AM-1 is an input transformer designed for various applications. This transformer ensures optimal signal transmission and isolation. It is suitable for use in research, development, and industrial settings.
- Model
- Ametek / EG&G / Princeton Applied Research AM-1
- Calibration
- Available on request
- Price
- $450
- RFQ ref
- AM-1
This unit
The Ametek/EG&G/Princeton Applied Research AM-1 is an input transformer engineered for low-source impedance applications to minimize noise when interfacing with high-input impedance preamplifiers. The 1:100 turns ratio provides impedance matching and signal conditioning for sensitive measurement systems. Optimized for source impedances below 100 ohms, the AM-1 delivers low-noise performance across its specified bandwidth.
Technical Specifications
- Turns Ratio: 1:100
- 3 dB Bandwidth: 1 kHz to 10 kHz at 10 ohms source impedance
- Noise Figure: Optimized for source impedances less than 100 ohms
Key Features The AM-1 is purpose-built for direct integration with precision preamplifiers in low-impedance source environments. Its fixed turns ratio provides predictable impedance transformation without adjustment. Performance is optimized when source impedance remains below 100 ohms, ensuring minimal noise contribution to the signal chain.
Typical Applications The AM-1 serves systems requiring signal conditioning from low-impedance sources prior to high-impedance preamplification. Common deployments include laboratory measurement setups, sensor interface applications, and instrumentation requiring low-noise performance at low source impedances.
Compatibility & Integration The AM-1 is recommended for use with the Princeton Applied Research Model 113 Low-Noise Preamplifier and is compatible with the AM-2 and Model 190 input transformers. Integration occurs at the preamplifier input stage, where the transformer conditions signals before amplification. The product family encompasses variations designated as AM-1, AM-2, II3, and Model 190, with cross-compatibility depending on application requirements and source impedance characteristics.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1 kHz to 10 kHz |
Ametek / EG&G / Princeton Applied Research AM-1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ametek / EG&G / Princeton Applied Research AM-1. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Ametek / EG&G / Princeton Applied Research AM-1 price
This Ametek / EG&G / Princeton Applied Research AM-1 is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ametek / EG&G / Princeton Applied Research AM-1 calibration cost
NIST-traceable calibration for the Ametek / EG&G / Princeton Applied Research AM-1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →