Ando AQ6310B 400-1750nm Optical Spectrum Analyzer
Ando AQ6310B,"Optical spectrum analyzer covering 400 to 1750 nm, ideal for characterizing broadband sources, DWDM systems, and passive optical components. Offers high dynamic range, fast measurement speeds, and sharp resolution for lab and field use."
- Model
- Ando AQ6310B
- Calibration
- Available on request
- Price
- $4,680
- Status
- In stock
- RFQ ref
- AQ6310B
This unit
The Ando AQ6310B is a precision optical spectrum analyzer for characterizing light sources, optical fibers, filters, and optical components across the 400–1750 nm wavelength range. It delivers wavelength accuracy to ±0.5 nm at 25°C and ±1 nm across the operating temperature range, with resolution bandwidth selectable from 0.1 to 10 nm depending on wavelength region. The instrument measures optical power from −70 to +10 dBm across its full range, with extended sensitivity to −80 dBm in the 600–1600 nm band.
High-speed sweep capability completes 100 nm spans in 1 second or less.
Technical Specifications
- Wavelength Range: 400–1750 nm
- Wavelength Accuracy: ±0.5 nm (25°C); ±1 nm (5–40°C)
- Wavelength Resolution: ±1 nm
- Resolution Bandwidth: 0.1–10 nm (540–1750 nm); 0.1–5 nm (400–540 nm)
- Sweep Width: 0.0–150 nm/div
- Sweep Time: ≤1 second (100 nm or less spans)
- Measurement Level Range: −70 to +10 dBm (400–1750 nm); −80 to +10 dBm (600–1600 nm)
- Level Linearity: ±0.2 dB/10 dB; ±0.5 dB/20 dB; +1 dB/60 dB
- Level Scale: 0.2–10 dB/div, LINEAR
- Optical Interface: FC connector
- Fiber Compatibility: 9/125 µm, 50/125 µm, 62.5/125 µm
- Power Supply: 100–120 VAC or 220–240 VAC, 50/60 Hz; ~150 VA
- Analog Output: 0–5 V (load ≥1 kΩ), 8NC connector
- Video Output: ~1 Vp-p, BNC (220–240 VAC only)
Key Features
- Peak search and half-width search functions
- Automatic measurement with function optimization
- Data averaging, subtraction, and normalization
- Wavelength calibration capability
- Three-dimensional and dominant waveform displays
- On-screen image hard-copy via integrated printer
- GP-IB standard interface for automation
Typical Applications Research and development, optical communications systems, laboratory spectral analysis, and optical component characterization.
Compatibility & Integration GP-IB interface enables integration into automated test systems. Analog output and video output support external data acquisition and monitoring workflows.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | −70 to +10 dBm (400–1750 nm) |
| −80 to +10 dBm (600–1600 nm) | Voltage / Current Range | 100–120 VAC or 220–240 VAC, 50/60 Hz |
| ~150 VA | Wavelength Range | 400–1750 nm |