LeCroy DA1822A Differential Amplifier, 10MHz
Lecroy Signal Conditioning Modules. Bandwidth: DC to 10 MHz, Accuracy: ±1% + termination resistance uncertainty, Accuracy: ±0.05%.
- Model
- Lecroy DA1822A
- Calibration
- Available on request
- Price
- $3,979
- RFQ ref
- DA1822A
This unit
The LeCroy DA1822A is a 10 MHz differential amplifier that conditions low-level differential signals for measurement on single-ended instruments including oscilloscopes, network analyzers, and spectrum analyzers. It delivers selectable gain from 1 to 1000 with a built-in input attenuator, enabling sensitivity enhancement down to 2 µV/div and precise characterization of power delivery networks and high-current shunt resistor voltages.
Technical Specifications
- Bandwidth: DC to 10 MHz
- Gain Settings: 1, 10, 100, or 1000 (selectable)
- Input Attenuator: Selectable ÷1 or ÷10, yielding effective gains of 0.1, 1, 10, 100, or 1000
- Risetime: < 35 ns at ×1 or ×10 gain
- Maximum Output: ±5 V into 50 Ω load
- Output Impedance: 50 Ω
- Gain Accuracy: ±1% + termination resistance uncertainty
- Attenuator Accuracy: ±0.05%
- Maximum Differential Linear Input: 5 V
- Equivalent Input Noise Voltage: < 9 nV/√Hz broadband at ×10 gain
- DC Drift: 50 µV/°C at ×10 gain
- Common Mode Rejection Ratio: 100,000 to 1 (frequency-dependent)
- Input Resistance (÷1 Attenuator): 1 MΩ or 100 MΩ
- Input Resistance (÷10 Attenuator): 1 MΩ
- Input Capacitance (÷10 Attenuator): 20 pF
- Input Leakage Current (Attenuator): < 10 pA at 0–45°C
- Input Protection: ±250 V with automatic disconnect and manual reset
- Input Range (÷1 Attenuator): ±15.5 V
- Input Range (÷10 Attenuator): ±155 V
Key Features
- Built-in Precision Voltage Generator (PVG) with 5½-digit resolution
- PVG voltage range: ±15.5 V (±10 V in differential offset mode)
- PVG DC accuracy: 0.05% + 500 µV via temperature-controlled oven
- Digital control with individual digit increment/decrement
- Autozero function at 0.0 V selection and periodic intervals
- PVG output available externally via rear panel connector
- Configurable as differential comparator input or internal offset voltage source
Typical Applications
- Measuring voltages across high-current shunt resistors
- Power structure loss characterization
- Low-voltage differential signal conditioning for single-ended measurement instruments
- Extended oscilloscope sensitivity for microvolt-level measurements
Compatibility & Integration Front panel differential inputs accept standard signal sources. Amplifier output and PVG voltage are available via rear panel connectors for instrument integration and external applications.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 10 MHz | Voltage / Current Range: ±15.5 V (÷1 attenuator), ±155 V (÷10 attenuator) |
Lecroy DA1822A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Lecroy DA1822A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Lecroy DA1822A price
This Lecroy DA1822A is listed at $3,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Lecroy DA1822A calibration cost
NIST-traceable calibration for the Lecroy DA1822A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →