Lecroy DA1855 High-performance Differential Amplifier, 100MHz
Lecroy Signal Conditioning Modules. Bandwidth: DC to 100 MHz, Resolution: 100 µV / 5-1/2 digit, Accuracy: 0.05% + 500 µV (15°C to 45°C).
- Model
- Lecroy DA1855
- Calibration
- Available on request
- Price
- $4,979
- RFQ ref
- DA1855
This unit
The LeCroy DA1855 is a differential amplifier delivering DC to 100 MHz bandwidth for precision signal conditioning across oscilloscopes, digitizers, and spectrum analyzers. Selectable gains of 1× and 10× combined with a 10× input attenuator provide effective gains of 10, 1, or 0.1 - with automatic display of combined effective gain accounting for probe, amplifier, and attenuator settings. An exceptional 100,000:1 (94 dB) CMRR and overdrive recovery enable accurate differential measurements in high-noise environments.
Technical Specifications
Bandwidth & Gain- Bandwidth: DC to 100 MHz
- Selectable gain: 1× and 10×
- Input attenuator: 10× selectable attenuation
- Effective gain display: Automatic combined gain calculation
- Bandwidth limit filters: 100 kHz, 1 MHz, 10 MHz, 20 MHz, or full 100 MHz Precision Voltage Generator (PVG)
- Output range: ±15.5 V (comparator mode); ±10 V (differential offset mode)
- Resolution: 100 µV / 5-1/2 digit
- DC accuracy: 0.05% + 500 µV (15°C to 45°C)
- PVG voltage accuracy: ±1% of reading ± 500 µV
- Temperature coefficient: <5 ppm/°C of full scale Performance Characteristics
- CMRR: 100,000:1 (94 dB) at DC; ≥50,000:1 (94 dB) at 70 Hz and 100 kHz; ≥316:1 (50 dB) at 10 MHz
- Overdrive recovery: From 400 V input signal to <100 mV (÷100 probe) in 100 ns; to <1 mV (10× gain) in 100 ns
- Input noise (10× gain): <4 nV/√Hz broadband
- DC drift (10× gain): 50 µV/°C
- Rise time: <3.5 ns typical Auto-Zero & Control
- Auto-zero: Adjusts DC balance on each gain change; sets output to zero when 0.0 V selected
- Control interface: Full control via ProBus from compatible Teledyne LeCroy oscilloscopes
Key Features
- Selectable bandwidth limiting via three 3-pole low-pass filters
- Front-panel PVG control with rear-panel output connector for external use
- Differential offset accuracy (referred to input) down to 0.1% + 50 µV + PVG error at 10× gain with ÷1 attenuator
Typical Applications High-speed data acquisition, communications signal integrity testing, and precision differential measurements where common-mode rejection and rapid overdrive recovery are critical.
Compatibility & Integration Direct instrument control via ProBus interface from Teledyne LeCroy oscilloscopes. External PVG output available for standalone differential comparator or offset voltage applications.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 100 MHz | Voltage / Current Range: ±15.5 V (comparator mode) |
Lecroy DA1855 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Lecroy DA1855. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Lecroy DA1855 price
This Lecroy DA1855 is listed at $4,979. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Lecroy DA1855 calibration cost
NIST-traceable calibration for the Lecroy DA1855 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →