Lambda / TDK / EMI DPP120-12-1

Lambda / TDK DC Power Supplies. Current: 2.8 A @ 115 VAC, Voltage: 12 VDC nominal (11.4–14.5 VDC operating range), Current: 10 A.

Model
Lambda / TDK DPP120-12-1
Calibration
Available on request
Price
$110
Status
In stock
RFQ ref
DPP120-12-1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The TDK-Lambda DPP120-12-1 is a 120 W single-output AC-DC power supply engineered for industrial control, factory automation, and test instrumentation. This enclosed DIN rail-mount unit delivers regulated 12 VDC output at up to 10 A, supporting universal AC input from 90–264 VAC and direct DC input from 210–370 VDC. Built for reliability across demanding environments, it combines convection cooling, metal construction, and 84% typical efficiency with active power factor correction to EN61000-3-2.

Technical Specifications Input Characteristics

AC Input: 90–264 VAC (auto-selectable ranges: 90–132 VAC or 186–264 VAC)

DC Input: 210–370 VDC

Input Frequency: 47–63 Hz

Input Current: 2.8 A @ 115 VAC; 1.4 A @ 230 VAC

Power Factor Correction: EN61000-3-2 compliant Output Characteristics

Output Voltage: 12 VDC nominal (11.4–14.5 VDC operating range)

Maximum Output Current: 10 A

Maximum Output Power: 120 W

Output Ripple and Noise: >50 mV (20 MHz bandwidth)

Isolation Voltage: 3 kV Performance

Efficiency: 84% typical

Operating Temperature Range: −35°C to +71°C (with derating)

Cooling Method: Convection

Key Features

Single regulated 12 VDC output with 10 terminal/9-pin interface

Universal AC/DC input acceptance with automatic voltage range selection

Compact enclosed design: 63.5 mm W × 125 mm H × 63.5–123.6 mm D

DIN rail mounting on TS35/7.5 or TS35/15 profile; 920 g weight

Certified to UL508, IEC/UL/CSA/EN62368-1, and 60950-1/UL60950-1/UL62368-1

RoHS Compliant (ROHS3) and REACH certified

Typical Applications

Motor control systems and industrial automation

Process control and factory instrumentation

Burn-in and test applications in chemical processing environments

Commercial IT equipment (ITE)

Compatibility & Integration DIN rail mounting on standard TS35 profile enables rapid panel integration. The 3 kV isolation voltage supports applications requiring galvanic separation. Input frequency tolerance of 47–63 Hz accommodates global mains standards.

Specifications

ParameterValue
Frequency Range47–63 Hz | Voltage / Current Range: 210–370 VDC input

Lambda / TDK DPP120-12-1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lambda / TDK DPP120-12-1. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lambda / TDK DPP120-12-1 price

This Lambda / TDK DPP120-12-1 is listed at $110. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lambda / TDK DPP120-12-1 calibration cost

NIST-traceable calibration for the Lambda / TDK DPP120-12-1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents