Keysight (Agilent) E2378A Rugged Handheld Multimeter, 3.5 Digit
Keysight / Agilent Laboratory Measurement Instruments. Voltage: 0.1 mV to 1000 V (100 µV resolution), Voltage: 0.1 mV to 750 V (1 mV resolution), Current: 0.1 µA to 10 A (100 nA resolution).
- Model
- Keysight / Agilent E2378A
- Calibration
- Available on request
- Price
- $145
- Status
- In stock
- RFQ ref
- E2378A
This unit
The Keysight E2378A is a rugged handheld multimeter engineered for field service, maintenance, and industrial troubleshooting in demanding environments. This 3.5-digit instrument delivers precision measurements across DC/AC voltage, current, resistance, continuity, and diode testing with a 3200-count digital display paired with a 32-segment analog bar graph. Auto-ranging and manual hold modes accommodate diverse measurement scenarios, while an audible continuity beep and data hold function enhance workflow efficiency.
Built for durability, the meter features overvoltage protection to 1000 V, splash-resistant construction, and extended battery life for extended field operations. A one-year calibration cycle supports metrological compliance in professional service environments.
Technical Specifications
- Display: 3.5-digit LCD, 3200 count with 32-segment analog bar graph
- Sampling Rate: Digital display ~2 times/second; analog bar graph ~12 times/second
- DC Voltage: 0.1 mV to 1000 V (100 µV resolution); 0.3% basic accuracy
- AC Voltage: 0.1 mV to 750 V (1 mV resolution); 1% basic accuracy; 1 kHz bandwidth
- DC Current: 0.1 µA to 10 A (100 nA resolution)
- AC Current: 0.1 µA to 10 A (100 nA resolution)
- Resistance: 0.1 Ω to 30 MΩ (0.1 Ω resolution); 0.7% basic accuracy
- Continuity: Audible beep at <50 Ω
- Diode Test: Included
- Overvoltage Protection: 1000 V
- Display Annunciators: Function, low-battery, and overload indicators
Key Features
- Auto-ranging or manual range hold selection
- Data hold function for measurement capture
- Compact, lightweight design for one-handed operation
- Long-lasting battery with low-battery indication
- Simple, intuitive control layout
Typical Applications
- Field service and on-site diagnostics
- Industrial maintenance and troubleshooting
- Electrical system commissioning and verification
- Harsh-environment equipment testing
Compatibility & Integration
- Operates independently as a portable, battery-powered instrument
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | AC 0.1 mV to 750 V, DC 0.1 mV to 1000 V, DC/AC 0.1 µA to 10 A |
Keysight / Agilent E2378A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent E2378A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keysight / Agilent E2378A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Keysight / Agilent E2378A price
This Keysight / Agilent E2378A is listed at $145. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keysight / Agilent E2378A calibration cost
NIST-traceable calibration for the Keysight / Agilent E2378A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →