Fluke 893A AC/DC Differential Voltmeter

Fluke Industrial Test Equipment. Model: 893A.

Model
Fluke 893A
Calibration
Available on request
Price
$450
Status
In stock
RFQ ref
893A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 893A Differential AC Voltmeter is engineered for accurate measurement of AC voltages. Its differential input allows for the rejection of common-mode noise, ensuring precise readings even in noisy environments. The instrument is built to deliver stable and repeatable measurements, making it an essential tool for professionals requiring high-accuracy voltage measurements.

Fluke 893A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 893A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 893A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 893A price

This Fluke 893A is listed at $450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 893A calibration cost

NIST-traceable calibration for the Fluke 893A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents