Keyence EX-V01 Controller for EX-305V Sensor Head

The Keyence EX-V01 is a controller unit designed for use with the EX-305V series sensor head. It processes signals from the sensor head to provide accurate and reliable detection in a variety of industrial automation applications. This controller offers high-speed response and easy setup.

Model
Keyence EX-V01
Calibration
Available on request
Price
$325
Status
In stock
RFQ ref
EX-V01
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keyence EX-V01 Controller is a dedicated amplifier unit that interfaces with the EX-305V inductive displacement sensor head to deliver high-speed, high-accuracy digital measurement for industrial automation. This controller processes analog sensor signals and provides multiple output formats - digital comparator outputs, strobe, alarm, and analog voltage - enabling integration into diverse control architectures. The EX-V01 achieves 0.075 ms response time at maximum speed with configurable 2-level threshold detection across four selectable patterns, supporting both NPN and PNP logic families.

Technical Specifications Power Supply: 24 VDC ±10%, maximum ripple 10% peak-to-peak, 240 mA current draw. Signal Processing: Maximum sampling rate of 40,000 samples per second (20,000 samples/sec with digital filter enabled). Response time 0.075 ms at full speed; OFF-delay time 60 ms. Sensor Head (EX-305V): 0 to 1 mm measuring range with ±0.3% linearity (F.S.). Resolution: 0.4 µm at 64-point averaging. Display updates 20 times per second on 7-segment, 2-color LED. Temperature coefficient 0.07% F.S./°C with iron targets (S45C, SS400, 1 mm thickness).

Key Features Output Options:

Digital outputs: HIGH, GO, LOW (NPN or PNP open-collector, 100 mA @ 40 V max for NPN; 100 mA @ 30 V max for PNP)

Strobe output: Normally Open, 100 mA max, 1 V residual voltage maximum

Alarm output: Normally Closed, 100 mA max, 1 V residual voltage maximum

Analog output: ±5 V, 100 Ω impedance, 0.075 ms response time Control Inputs: NPN open-collector or non-voltage contact; PNP accepts 10–30 V applied voltage. Supports timing, reset, auto-zero, comparator disable, synchronous, and external setting functions. Threshold Setting: Upper/lower 2-level configuration with four selectable comparison patterns.

Typical Applications Precision displacement measurement in manufacturing metrology, quality control inspection, positioning feedback, and dimensional verification where sub-micron resolution and millisecond response times are required.

Compatibility & Integration Designed exclusively for the Keyence EX-305V sensor head. Available in EX-V01 (NPN) and EX-V01P (PNP) variants to match existing plant control logic.

Specifications

ParameterValue
Voltage / Current Range24 VDC ±10%, 240 mA max

Keyence EX-V01 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keyence EX-V01. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keyence EX-V01 faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

Keyence EX-V01 price

This Keyence EX-V01 is listed at $325. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keyence EX-V01 calibration cost

NIST-traceable calibration for the Keyence EX-V01 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents