Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R 3-Phase SixSCR Firing Board

The Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R is a 3-Phase SixSCR Firing Board designed for precise control of three-phase SCR power converters. It offers reliable and efficient firing of six silicon-controlled rectifiers in various industrial applications.

Model
Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R
Calibration
Available on request
Price
$850
Status
In stock
RFQ ref
FCOG6100-01-0-5/6-2-0-48-1-1-1-R
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R is a 3-phase six-SCR firing board that delivers precise phase-angle control for SCR power converters and AC controllers. This board generates high-current gate drive pulses to independently fire six silicon-controlled rectifiers in industrial power control systems. It operates across 45–65 Hz line frequencies with configurable 50/60 Hz tuning, and revision R incorporates enhanced compensation circuitry that reduces delay angle variance - approximately 5° shift from 60 to 50 Hz operation. The board accepts analog delay angle command inputs and produces isolated gate drives with high current pulse capability, making it suitable for demanding three-phase AC/DC conversion applications.

Technical Specifications

Mains Frequency: 45–65 Hz; configurable for 50/60 Hz. Revision R gate drive angle shift: ~5° for 60→50 Hz transition

Mains Voltage: 480 V SCR configuration

On-Board Transformer: 120–240 Vac primary; external power source

Board Supply Options: 30 VDC or 24 VAC external; 120/240/380/480 V via on-board transformer; SCR cathode connections

Regulated Outputs: +12 VDC ±5% at J3-6 (20 mA max); +5 VDC ±5% at J3-7 (5 mA max)

Gate Drive Pulses: High-current picket fence architecture. Initial pulse: 15 V open circuit / 1.8 A short circuit. Sustaining pulses: 7 V open circuit / 0.5 A short circuit

Gate Pulse Burst Frequency: 384× mains voltage frequency

Pulse Transformer Isolation: 3500 VRMS

VCO Control Voltage: ~5.0 VDC at TP2 (factory-set)

Command Signal Input: Analog delay angle (SIG HI), configurable voltage/current ranges

SCR Configuration: Six SCRs, 3-phase, no parallel SCR option

Key Features

Six independently isolated gate drives for individual SCR control

Phase-angle control topology optimized for AC controller and DC converter duty

Soft-start/soft-stop inputs (independently configurable)

On-board phase references included

Low frequency variance drift in revision R

Typical Applications

Three-phase AC motor controllers

SCR-based DC power supply regulation

Industrial power conversion and load control systems

Compatibility & Integration Part of the CVR600 Firing/Regulator System family. Configuration code -01-0-5/6-2-0-48-1-1-1-R specifies six-SCR AC controller topology, no regulator board connection, and 480 V system voltage.

Specifications

ParameterValue
Frequency Range45–65 Hz (configurable 50/60 Hz) | Voltage / Current Range: Board supply: 24 VAC or 30 VDC external
120/240/380/480 V via transformer. Outputs+12 VDC ±5% @ 20 mA
+5 VDC ±5% @ 5 mA. Gate drive initial15 V OC / 1.8 A SC
sustaining7 V OC / 0.5 A SC

Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R price

This Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R calibration cost

NIST-traceable calibration for the Enerpro FCOG6100-01-0-5/6-2-0-48-1-1-1-R is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents