Ault Korea / Power General FLU2-40-6 Dual Output Power Supply

Ault Korea / Power General DC Power Supplies. Voltage: ** 85–265 VAC (single phase) or 100–370 VDC.

Model
Ault Korea / Power General FLU2-40-6
Calibration
Available on request
Price
$110
Status
In stock
RFQ ref
FLU2-40-6
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Ault Korea FLU2-40-6 is a 40 W open-frame switching power supply delivering dual independent outputs across a wide input range. Built on a flyback converter topology with fixed 40 kHz operation, it accepts universal AC input of 85–265 VAC at 47–440 Hz or 100–370 VDC, making it suitable for global deployment and battery-backed systems. The unit achieves an MTBF exceeding 200,000 hours and maintains output ripple and noise below 1% peak-to-peak maximum.

Technical Specifications

Output Power: 40 W maximum, dual output configuration

Input Voltage: 85–265 VAC (single phase) or 100–370 VDC

Input Frequency: 47–440 Hz (AC input)

Operating Frequency: 40 kHz fixed

Efficiency: 62–75% typical at nominal input and load conditions

Output Noise & Ripple: 1% peak-to-peak maximum

Isolation: 5300 VDC input-to-output (one minute)

Hold-Up Time: 16 ms at 115 VAC; 32 ms at 230 VAC (minimum, full load)

Operating Temperature: −20°C to +70°C (derates 2%/°C above +50°C)

Temperature Coefficient: ±0.05%/°C across operating range

Storage Temperature: −40°C to +85°C

Relative Humidity: 0–95% non-condensing

Altitude: 0–10,000 feet

Key Features

Continuous over-current and short-circuit protection with primary output over-voltage protection

MOV transient protection with on-board input line fuse

EMI filter surpasses EN55022/FCC Class B by 10 dB typical

Primary output adjustable ±5%; auxiliary outputs fixed

Soft start on all models

No minimum load requirement (0% operation supported)

Convection cooling with optional forced-air capability for confined installations

Typical Applications Industrial control systems, telecommunications equipment, embedded computing, and networked devices requiring isolated dual-rail supplies with international AC or DC sourcing.

Compatibility & Integration Hi-pot rated for 5300 VDC isolation. Fixed 40 kHz switching minimizes EMI in adjacent frequency bands. Primary output voltage trimming enables system-level regulation without external post-regulators.

Specifications

ParameterValue
Frequency Range40 kHz fixed
input frequency 47–440 Hz (AC) | Voltage / Current Range85–265 VAC or 100–370 VDC input

Ault Korea / Power General FLU2-40-6 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ault Korea / Power General FLU2-40-6. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Ault Korea / Power General FLU2-40-6 price

This Ault Korea / Power General FLU2-40-6 is listed at $110. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ault Korea / Power General FLU2-40-6 calibration cost

NIST-traceable calibration for the Ault Korea / Power General FLU2-40-6 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →