Kimmon IK Series He-Cd Laser Model IK3083R-DB Calibrated

The Kimmon IK Series He-Cd Laser Model IK3083R-DB is a calibrated Helium-Cadmium laser designed for scientific and industrial applications. It emits a stable, coherent beam of light at specific wavelengths. Known for its reliability and precision, this laser is suitable for use in spectroscopy, microscopy, and materials processing.

Model
Kimmon IK3083R-DB
Calibration
Available on request
Price
$2,335
Status
In stock
RFQ ref
IK3083R-DB
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Kimmon IK Series IK3083R-DB is a calibrated Helium-Cadmium gas laser delivering stable, coherent UV light at 325 nm for scientific and industrial measurement, inspection, and materials processing. This Class 3B continuous-wave system generates 10 mW of output power in a diffraction-limited TEM00 mode with exceptional beam quality and pointing stability.


Technical Specifications

Optical Performance

  • Wavelength: 325 nm (UV)

  • Output Power (CW): 10 mW

  • Transverse Mode: TEM00

  • Polarization: Linear, > 500:1 ratio

  • Beam Diameter (1/e²): < 1.0 mm at 100 mm from output coupler

  • Beam Divergence: < 0.4 mrad

  • Beam Pointing Stability: ±25 μrad (at 25°C constant temperature)

  • Power Stability: ±2% over 4 hours at 25°C; < 20% across 10–40°C operating range

  • RMS Noise: 2.0% RMS; 500:1 ratio enables compatibility with polarization-sensitive instrumentation. Tight beam pointing stability of ±25 μrad supports long-distance alignment in metrology and interferometric systems. Helium-cadmium gas discharge provides exceptional wavelength stability essential for spectroscopy and calibration work.


Typical Applications Photoluminescence, Raman spectroscopy, flow cytometry, fluorescence imaging, semiconductor inspection, holography, lithography, photopolymer exposure, interferometry, defect inspection, precision measurement, and materials processing.


Compatibility & Integration Laser head and power supply integrate via internal control circuit board, enabling straightforward head replacement. Power supply model KP2014C is compatible with this He-Cd system. Operating temperature: 10–40°C; Storage: -10 to 50°C.

Specifications

ParameterValue
Voltage / Current Range100-240 VAC input
70-95 mA tube current | Wavelength Range325 nm

Kimmon IK3083R-DB — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Kimmon IK3083R-DB. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Kimmon IK3083R-DB faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.

Kimmon IK3083R-DB price

This Kimmon IK3083R-DB is listed at $2,335. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Kimmon IK3083R-DB calibration cost

NIST-traceable calibration for the Kimmon IK3083R-DB is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents