CASIX LDC-1500 Laser Diode Controller

The CASIX LDC-1500 is a precision laser diode controller designed for laboratory and industrial applications. It provides stable and accurate current and temperature control for laser diodes, ensuring optimal performance and longevity. With its user-friendly interface and comprehensive protection features, the LDC-1500 is an ideal solution for demanding laser diode control requirements.

Model
CASIX LDC-1500
Calibration
Available on request
Price
$650
Status
In stock
RFQ ref
LDC-1500
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

A CASIX LDC-1500 is a precision laser diode controller engineered for laboratory and industrial environments, providing stable and accurate current and temperature regulation for laser diodes. This controller can ensure optimal laser diode performance and extend operational lifespan. It features a user-friendly interface and incorporates comprehensive protection mechanisms, making it a suitable choice for applications requiring precise laser diode control.

Technical Specifications Electrical Specifications:

  • Input Voltage Range: AC 100-240V, 50/60Hz
  • Output Power: The LDC-1500 series offers various output wattage configurations, including models with 16W, 17.5W, 33W, and 34.5W total wattage. Specific configurations like LDC15F-1 and LDC15F-2 denote different wattage capabilities.
  • Output Voltages: Available output voltages include +5V, +12V, -12V, +15V, and -15V, depending on the specific model configuration.
  • Current Capacity: Peak load currents are supported for durations of 10 seconds or less, provided the total wattage remains within the rated limits. For models where the +5V load is 0A, other outputs can draw up to 80% of their rated current.
  • Line Regulation: * ±5V: 20mV max * ±12V: 48mV max * ±15V: 60mV max
  • Temperature Regulation: * ±5V: 50mV max * ±12V: 350mV max * ±15V: 420mV max
  • Ripple and Noise: * ±5V: 120mVp-p max (at 0 to +50°C) * ±12V, ±15V: 150mVp-p max (at 0 to +50°C) * ±5V: 150mVp-p max (at -10 to 0°C) * ±12V, ±15V: 160mVp-p max (at -10 to 0°C)
  • Efficiency: Approximately 72% typical at full load for certain configurations (e.g., LDC15F-1).
  • Startup Time: Maximum 200ms at AC 85V input and 100% load.
  • Leakage Current: 0.75mA max (at 60Hz, according to UL, CSA, VDE, and DEN-AN standards).
  • Insulation: * Input-FG: AC 2000V for 1 minute, cutoff current 10mA. DC 500V, 50MΩ min. * Output-FG: AC 500V for 1 minute, cutoff current 100mA. DC 500V, 50MΩ min. * Output-Output (V1-V2, V3): AC 100V for 1 minute, cutoff current 100mA. DC 100V, 10MΩ min. Environmental Specifications:
  • Operating Temperature: -10°C to +60°C (derating required for operation with chassis and cover).
  • Operating Humidity: 20% to 90% RH (non-condensing).
  • Operating Altitude: Up to 3,000m (10,000 feet).
  • Storage Temperature: -20°C to +75°C.
  • Storage Humidity: 20% to 90% RH (non-condensing).
  • Storage Altitude: Up to 9,000m (30,000 feet).
  • Vibration: 10-55Hz, 19.6m/s² (2G), 3-minute period, 60 minutes each along X, Y, and Z axes.
  • Impact: 196.1m/s² (20G), 11ms, once each along X, Y, and Z axes. Physical Specifications:
  • Case Size: 50 x 26 x 127mm (W x H x D) for some models.
  • Weight: 150g max (unit only), 300g max (with chassis and cover).
  • Cooling Method: Convection. Safety and Noise Regulations:
  • Agency Approvals: Complies with UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1, DEN-AN, and IEC60950-1.
  • Conducted Noise: Complies with FCC-B, CISPR22-B, EN55022-B, and VCCI-B standards. Ordering Information (Example for LDC15F): The ordering format typically follows a structure like LDC15F-1-O, where:
  • LDC indicates the series name.
  • The number (e.g., 15) denotes wattage.
  • F signifies the type (e.g., Open Frame).
  • The subsequent number (e.g., -1) indicates the output configuration.
  • An optional suffix (e.g., -O) can denote specific features like chassis, cover, or potentiometer. Common options include: * C: With coating * G: Low leakage current * S: With chassis * SN: With chassis & cover * Y: With Potentiometer

Compatibility The CASIX LDC-1500 can be compatible with a wide range of laser diodes requiring precise current and temperature control. Its universal input voltage range (AC 100-240V) ensures compatibility with standard power grids in the USA and other regions. Specific compatibility with particular laser diode models would depend on the current and voltage requirements of those diodes, which should be matched against the LDC-1500's output specifications.

Why Choose Aumictech for CASIX LDC-1500? At Aumictech, we specialize in supplying high-precision laser diode control instrumentation. Whether you need reliable current and temperature stabilization for sensitive laser diodes, solid protection features to safeguard your investment, or a user-friendly interface for seamless operation, our team ensures the CASIX LDC-1500 delivers maximum performance and longevity for your critical laser applications.

CASIX LDC-1500 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the CASIX LDC-1500. Calibration covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common CASIX LDC-1500 faults: blown I/O fuses, failed analog modules, power supply capacitor failure. Common faults include blown I/O protection fuses, failed analog I/O modules, power supply capacitor failure, and serial or Ethernet communication port damage.

CASIX LDC-1500 price

This CASIX LDC-1500 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

CASIX LDC-1500 calibration cost

NIST-traceable calibration for the CASIX LDC-1500 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers I/O channel accuracy per specification, analog output and input calibration to rated accuracy, and functional communication interface test (serial, Ethernet, fieldbus). Turnaround is 1 to 3 business days after receipt. See full calibration details →