Ixia LM622MR

The Ixia LM622MR is a load module designed for network performance testing. It supports OC-192/STM-64 data rates and is used to generate and analyze high-volume traffic for evaluating network infrastructure.

Model
Ixia LM622MR
Calibration
Available on request
Price
$2,800
Status
In stock
RFQ ref
LM622MR
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Ixia LM622MR is a 2-port load module engineered for high-volume traffic generation and packet analysis in network performance testing environments. It supports OC-3 and OC-12c data rates over Packet over SONET/SDH (POS) interfaces, enabling comprehensive evaluation of network infrastructure performance and capacity. The module integrates into Ixia chassis platforms and operates with Ixia server software including Ixserver and Ixplorer, providing sophisticated traffic generation and analysis capabilities for carrier-class network validation.

Technical Specifications

Interface Type: OC-3/OC-12c Packet over SONET/SDH (POS)

Data Rates: OC-3 and OC-12c

Port Configuration: 2 ports

Technology Support: ATM and POS (Packet Over SONET/SDH)

Module Type: Load Module

Storage Temperature: 5°C to 50°C (41°F to 122°F)

Operating Humidity: 0% to 85% non-condensing

Key Features

High-density traffic generation for performance evaluation

Dual-port architecture for concurrent testing scenarios

Native support for both ATM and POS protocols

Integration with established Ixia chassis ecosystem

Advanced packet analysis and traffic characterization

Typical Applications

SONET/SDH network performance validation

Carrier backbone testing and capacity planning

POS interface stress testing and protocol compliance

High-volume traffic generation for edge router evaluation

Network infrastructure performance benchmarking

Compatibility & Integration The LM622MR mounts directly into Ixia chassis platforms and operates with Ixserver and Ixplorer server software. Ixia client applications are available separately and require a valid logon account for download. Server software is bundled with the module.

Ixia LM622MR — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ixia LM622MR. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Ixia LM622MR faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Ixia LM622MR price

This Ixia LM622MR is listed at $2,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ixia LM622MR calibration cost

NIST-traceable calibration for the Ixia LM622MR is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →