Lambda / TDK / EMI LRS 58-24
The Lambda LRS 58-24 is a highly reliable and efficient enclosed power supply, designed for a wide range of industrial and electronic applications. It features a universal AC input, compact size, and excellent thermal performance. Built with quality components, it ensures stable and dependable operation.
- Model
- Lambda / TDK / EMI LRS 58-24
- Calibration
- Available on request
- Price
- $340
- Status
- In stock
- RFQ ref
- LRS 58-24
This unit
The Lambda TDK LRS 58-24 is an enclosed, convection-cooled DC power supply delivering 24 Vdc at up to 44 A (1440 W) from universal AC or DC input. Built for industrial and electronic applications requiring high reliability, tight regulation, and low noise in demanding environments, this supply operates continuously from −10°C to +71°C and meets multiple military and safety certifications.
Technical Specifications
Input & Output- Input voltage: User-selectable 95–132 VAC or 187–265 VAC, 47–440 Hz; DC input 145 Vdc ±10%
- Output voltage: 24 Vdc nominal, ±5% tolerance
- Maximum output current: 44 A (currents 10–15% higher without cover)
- Maximum output power: 1440 W at 24 V Performance
- Minimum efficiency: 80%
- Line regulation: 0.1% (low to high line)
- Load regulation: 0.1% (no load to full load)
- Output ripple and noise: 15 mV RMS, 100 mV peak-to-peak (20 MHz bandwidth)
- Remote sensing provision to eliminate lead resistance effects Protection & Control
- Overvoltage protection: Standard (AC recycle required for reset)
- Overload protection: Automatic electronic self-resetting current limiting
- Inrush current: Limited during cold start Environmental
- Operating temperature: −10°C to +71°C continuous (derating above 40°C); guaranteed turn-on at −20°C
- Storage temperature: −55°C to +85°C
- Conducted EMI: FCC Docket 20780 Class A; MIL-STD-461A Notice 4 CE04; VDE 0871 Class A
- Environmental qualification: MIL-STD-810C (low/high temperature, shock, vibration, humidity, fungus, pressure-altitude)
Key Features
- Convection cooled - no fans or blowers required
- UL Recognized, CSA Certified, TUV Licensed
- Barrier strip input terminals; heavy-duty threaded bus bars for output
- Tapped mounting holes; customer-provided clearance around vent holes required
Typical Applications Industrial automation, test systems, instrumentation, and distributed power where stable 24 V rails and high current capacity are essential.
Compatibility & Integration Dual-input design accommodates both standard 120/240 VAC facilities and 145 Vdc sources. Remote sensing terminals enable precision voltage regulation across extended distribution networks.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 47–440 Hz | Voltage / Current Range: 95–132 VAC or 187–265 VAC (AC input) |
Lambda / TDK / EMI LRS 58-24 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Lambda / TDK / EMI LRS 58-24. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Lambda / TDK / EMI LRS 58-24 price
This Lambda / TDK / EMI LRS 58-24 is listed at $340. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Lambda / TDK / EMI LRS 58-24 calibration cost
NIST-traceable calibration for the Lambda / TDK / EMI LRS 58-24 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →