Anritsu MA2410xA – Inline Peak Power Sensor

Anritsu RF Power Sensors. Bandwidth: ** Selectable at 4 MHz (full), Bandwidth: ** 100 Hz.

Model
Anritsu MA2410xA
Calibration
Available on request
Price · starting from
$1,900
Status
In stock
RFQ ref
MA2410xA
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MA2410xA Inline Peak Power Sensor measures pulsed and modulated signals with True-RMS accuracy across a wide dynamic range and frequency spectrum. Dual-path architecture enables simultaneous forward and reverse power measurement, making it ideal for transmission line verification without system downtime. The sensor handles CW, multi-tone, and digitally modulated formats including GSM/EDGE, CDMA/EV-DO, WCDMA/HSDPA, WiMAX, and TD-SCDMA. Two models cover different frequency bands: the MA24103A spans 25 MHz to 1 GHz, while the MA24105A extends to 4 GHz. Both operate from 2 mW to 150 W in continuous mode, with pulse capability to 300 W. Inline, bi-directional design minimizes installation complexity in active systems.

Technical Specifications

Measurement Range: 2 mW to 150 W (+3 dBm to +51.76 dBm); pulse peak to 300 W (+54.77 dBm)

Frequency Range:

MA24103A: 25 MHz to 1 GHz

MA24105A: 350 MHz to 4 GHz

True-RMS Measurements: Supported across entire frequency and dynamic range

Peak Signal Bandwidth: Selectable at 4 MHz (full), 200 kHz, or 4 kHz

Average Signal Bandwidth: 100 Hz

Insertion Loss (typical): - ≤0.15 dB from 25 MHz to 1.25 GHz - ≤0.20 dB above 1.25 GHz to 4 GHz

Input Return Loss (typical): - ≥29.5 dB from 25 MHz to 3 GHz - ≥26.5 dB above 3 GHz to 4 GHz

Key Features

Forward path measures Peak Envelope Power (PEP), crest factor, CCDF, and burst average power

Reverse path measures reflection coefficient, return loss, and VSWR

Bi-directional measurement of transmitted and reflected power

4 MHz bandwidth channel on forward path

Typical Applications Transmission line characterization, modulated signal power analysis, antenna matching verification, and multi-standard wireless signal measurement.

Compatibility & Integration Operate via USB with Microsoft Windows (including Windows 11) on a PC, or connect to compatible Anritsu handheld instruments. PowerXpert™ application (v2.11 or greater) provides data logging, power-versus-time graphs, real-time settings control, and offset tables for calibrated measurements.

Specifications

ParameterValue
Frequency RangeMA24103A: 25 MHz to 1 GHz
MA24105A350 MHz to 4 GHz | Power Range (dBm): '+3 dBm to +51.76 dBm (continuous)

Anritsu MA2410xA — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2410xA. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu MA2410xA price

This Anritsu MA2410xA is listed at $1,900. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MA2410xA calibration cost

NIST-traceable calibration for the Anritsu MA2410xA is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →