JDS Uniphase MAPB+1E1550FP0 Model BBS / MAP Broadband Source

The JDS Uniphase MAPB+1E1550FP0 Model BBS is a MAP Broadband Source, designed for various optical testing and measurement applications. This broadband source provides a stable and reliable optical output, making it suitable for characterizing optical components and systems. Its solid design ensures consistent performance in demanding environments.

Model
JDS Uniphase MAPB+1E1550FP0
Calibration
Available on request
Price
$2,780
Status
In stock
RFQ ref
MAPB+1E1550FP0
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase MAPB+1E1550FP0 Model BBS is a MAP Broadband Source cassette that generates spectrally flattened amplified spontaneous emission (ASE) across the C-band using erbium-doped fiber technology. Operating from 1527 nm to 1568 nm, this source delivers stable, high-power-density output suitable for optical component characterization, system compliance validation, OSNR measurements, and test equipment calibration. The unit integrates directly into the JDS Uniphase Multiple Application Platform (MAP) chassis, providing modular functionality in a compact form factor.


Technical Specifications



  • Product Type: MAP Broadband Source Cassette

  • Optical Output: Amplified Spontaneous Emission (ASE)

  • Wavelength Range: 1527 nm to 1568 nm (C-band)

  • Output Power: 50 mW or 100 mW options

  • Spectral Gain Flatness: ≤1.6 dB maximum

  • Total Output Power Stability: ±0.02 dB

  • Output Isolation: ≥46 dB

  • Optical Interface: FC/PC

  • Operating Temperature: 0 to 50 °C

  • Storage Temperature: −40 to 70 °C

  • Humidity: Maximum 95% RH non-condensing (0 to 45 °C)

  • Safety Compliance: IEC 60825-1 (2002) Class 3B; 21 CFR 1040.10; CE, UL3101-1, CAN/CSA-C22.2 No.1010.1


Key Features



  • Flattened output power spectrum across C-band for consistent spectral performance

  • High output power density enables efficient optical testing

  • Superior spectral stability ensures repeatable, reliable measurements

  • Cassette form factor optimized for MAP system integration

  • Selectable output power accommodates various test requirements


Typical Applications



  • Optical component spectral characterization

  • Systems compliance and performance validation

  • Optical signal-to-noise ratio (OSNR) experimentation

  • Test equipment calibration and verification

  • Active and passive component noise source testing

  • Sensor and imaging system evaluation


Compatibility & Integration Designed exclusively for integration within the JDS Uniphase Multiple Application Platform (MAP) chassis. Dimensions (benchtop BBS configuration): 21.2 × 8.9 × 35.5 cm; weight: <4 kg.

Specifications

ParameterValue
Wavelength Range1527 nm to 1568 nm

JDS Uniphase MAPB+1E1550FP0 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase MAPB+1E1550FP0. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase MAPB+1E1550FP0 faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.

JDS Uniphase MAPB+1E1550FP0 price

This JDS Uniphase MAPB+1E1550FP0 is listed at $2,780. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase MAPB+1E1550FP0 calibration cost

NIST-traceable calibration for the JDS Uniphase MAPB+1E1550FP0 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →