ADInstruments ML228 Octal Bridge Amp
The ADInstruments ML228 Octal Bridge Amp is a versatile octal bridge amplifier designed for a range of physiological measurements. It provides eight independent channels of bridge amplification, enabling simultaneous recording from multiple transducers. Ideal for research applications requiring precise and stable signal amplification.
- Model
- ADInstruments ML228
- Calibration
- Available on request
- Price
- $750
- RFQ ref
- ML228
This unit
The ADInstruments ML228 Octal Bridge Amp is an eight-channel front-end amplifier for PowerLab systems, delivering precise signal conditioning from DC bridge transducers. It amplifies physiological signals across force, displacement, pressure, temperature, and light measurement applications with ±0.5% accuracy and software-controlled zeroing.
Technical Specifications
Amplification:- 8 independent channels with differential input configuration
- Gain range: ±200 μV to ±5 V full scale in 14 steps (±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV, ±50 mV, ±20 mV, ±10 mV, ±5 mV, ±2 mV, ±1 mV, ±500 μV, ±200 μV)
- Amplification accuracy: ±0.5% (combined with PowerLab)
- Input impedance: 2 MΩ (differential), 2 × 1 MΩ (single-ended)
- Maximum input voltage: ±10 V Signal Conditioning:
- Common-mode rejection ratio: 100 dB at 50 Hz (typical)
- Input noise: <1 μV
- Frequency response (-3 dB): 2 kHz maximum at all gains
- Low-pass filtering: 1 Hz to 2 kHz in eight software-selectable steps
- Internal offset range: ±10 V (1–5 V), ±1 V (100–500 mV), ±100 mV (200 μV–50 mV)
- Internal offset resolution: 16-bit DAC, ±32,000 steps about 0 V Transducer Interface:
- Eight-pin DIN socket inputs per channel
- Excitation voltage: 0–20 V DC (±10 V referred to ground), externally adjustable
- Transducer drive current: ±45 mA maximum
- Supports powered bridge transducers and certain low-impedance unpowered transducers
- Compatible with Grass transducers via MLAC11 adapter cable
Key Features
- Software-controlled manual or automatic zeroing with fast engagement
- Individual overload indicator light per channel (illuminates on out-of-compliance conditions)
- BNC analog output sockets on rear panel
- Power consumption: 5.0 W (without transducers)
Typical Applications Force and strain measurement, displacement and position sensing, pressure transduction, temperature monitoring, and light intensity quantification in physiological research.
Compatibility & Integration Connects to PowerLab systems via I2C port (power and control bus). I2C communication rate approximately 50 Kbits/s. Multiple front-end units supported depending on PowerLab model.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 2 kHz | Voltage / Current Range: ±10 V max input, ±200 μV to ±5 V full scale, ±45 mA max drive, 0–20 V excitation |
ADInstruments ML228 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the ADInstruments ML228. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
ADInstruments ML228 price
This ADInstruments ML228 is listed at $750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
ADInstruments ML228 calibration cost
NIST-traceable calibration for the ADInstruments ML228 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →