Anritsu MS46522B – ShockLine™ 2-Port Performance Vector Network Analyzer
The Anritsu MS46522B ShockLine™ is a 2-Port Performance Vector Network Analyzer (VNA) that delivers wide frequency coverage and high performance for S-parameter measurements. It is ideal for testing RF and microwave components and systems in manufacturing, R&D, and education environments.
- Model
- Anritsu MS46522B
- Calibration
- Available on request
- Price
- $38,000
- RFQ ref
- MS46522B
This unit
The Anritsu MS46522B ShockLine™ 2-Port Performance Vector Network Analyzer delivers S-parameter and time-domain measurements across passive RF and microwave devices. Five frequency configurations span 50 kHz to 92 GHz, with dynamic range to 137 dB and output power up to +13 dBm. The 3U chassis integrates SmartCal™ auto-calibration, time gating, and optional advanced time-domain signal integrity testing.
LAN remote control and graphical interface support manufacturing, R&D, and educational workflows.
Technical Specifications
Frequency Coverage- MS46522B-010: 50 kHz to 8.5 GHz
- MS46522B-020: 50 kHz to 20 GHz
- MS46522B-043: 50 kHz to 43.5 GHz
- MS46522B-082: 55 GHz to 92 GHz (1-meter tethers)
- MS46522B-083: 55 GHz to 92 GHz (5-meter tethers) Performance Metrics
- Dynamic Range: Up to 137 dB
- Maximum Output Power: +13 dBm (default 0 dBm; +5 dBm on select models)
- Power Degradation: 0.5 dB above 8.5 GHz to 25 GHz; 1 dB above 25 GHz to 40 GHz (Options 20, 43)
- Port Match (worst of source/load): >21 dB Ports 1–2 (300 kHz–4 GHz); >15 dB both ports (4 GHz–40 GHz)
- Directivity: Excellent corrected directivity minimizes measurement uncertainty
- High Level Noise: Typically 0.005 dB magnitude and 0.05° phase (simultaneous sweep); up to 0.003 dB rms degradation in 100 MHz window around 1 GHz Operating Conditions
- Warm-Up Time: 45 minutes
- Operating Temperature: 25 °C ± 5 °C
- Calibration Cycle: Recommended 12 months
Key Features
- SmartCal™ auto-calibration reduces setup overhead
- S-parameter and time-domain measurement modes
- Bandpass and lowpass time-domain modes (Option -002)
- Lowpass TDR-like display for impedance characterization
- Advanced Time Domain option for signal integrity testing
- Time gating for rapid fault identification
- Tethered source/measurement modules for E-band (55–92 GHz)
- 1-meter tethers (Option 82) for benchtop; 5-meter tethers (Option 83) for OTA chambers
Typical Applications
- Passive component characterization and validation
- Signal integrity and transmission line analysis
- Manufacturing test and process control
- Research and development of RF/microwave devices
- Educational laboratory measurements
Compatibility & Integration LAN-based remote control enables instrument integration into automated test systems and distributed measurement environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 50 kHz to 92 GHz (model-dependent: 50 kHz–8.5 GHz, 50 kHz–20 GHz, 50 kHz–43.5 GHz, 55–92 GHz) | Power Range (dBm): '-13 dBm to +13 dBm output power (default 0 dBm |
Anritsu MS46522B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MS46522B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MS46522B price
This Anritsu MS46522B is listed at $38,000. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MS46522B calibration cost
NIST-traceable calibration for the Anritsu MS46522B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →