Eaton / MTL Instruments MTL5082 Resistance Isolator

The MTL5082 Resistance Isolator is a galvanically isolated interface unit designed to transfer resistance signals from hazardous areas to safe areas. It provides isolation and signal conversion for resistance temperature detectors (RTDs), slidewire potentiometers, and other resistance-based sensors, ensuring safe and reliable operation in industrial environments.

Model
Eaton / MTL Instruments MTL5082
Calibration
Available on request
Price
$245
RFQ ref
MTL5082
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Eaton / MTL Instruments MTL5082 is a single-channel resistance isolator that transfers resistance signals from hazardous areas to safe areas with galvanic isolation. It accommodates 2-, 3-, or 4-wire RTDs and other resistance sensors conforming to BS 1904/DIN 43760 standards, making it ideal for Zone 0, IIC, T4 and Div 1, Group A hazardous locations. The module accepts resistance inputs from 10Ω to 400Ω with 200μA nominal excitation current and delivers isolated 2-, 3-, or 4-wire outputs in the same range. User-selectable wire configuration via onboard switches allows factory-set defaults (typically 3-wire) to be modified in the field. Output safety drive responds to open-circuit sensor conditions by upscaling to 420Ω nominal, meeting EN50020:1994 simple apparatus requirements. The isolator provides 250V RMS galvanic isolation between input, output, and power supply terminals. Temperature drift measures ±10mΩ/°C typical (0.01%/°C @ 100Ω), with response time to within 4% of final value within 1 second. Powered from 20 to 35V dc supplies, the module consumes 55mA at 24V, 65mA at 20V, or 45mA at 35V. DIN-rail mounting ensures compact integration in distributed control systems. The MTL5082 offers an alternative to the MTL5074 for applications where native resistance output is preferred over current-loop conversion.

Specifications

ParameterValue
Voltage / Current Range20–35V dc supply

Eaton / MTL Instruments MTL5082 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Eaton / MTL Instruments MTL5082. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Eaton / MTL Instruments MTL5082 price

This Eaton / MTL Instruments MTL5082 is listed at $245. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Eaton / MTL Instruments MTL5082 calibration cost

NIST-traceable calibration for the Eaton / MTL Instruments MTL5082 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →