Agilent/Keysight N4962A
Agilent / Keysight Bit Error Rate Testers (BERT). Frequency Range: 0.5 to 12.5 GHz (with external clock); 9.90 to 11.35 GHz (internal clock); External clock input 618.75 to 709.375 MHz, Voltage / Current Range: External clock: 2 Vpp max; RX clock input: 1–2 Vpp; Clock outputs: 1 Vpp typical; HF trigger: 1.3 Vpp typical; LF trigger: 0.5 Vpp typical; Jitter injection: 2 Vpp max.
- Model
- Agilent / Keysight N4962A
- Calibration
- Available on request
- Price
- $19,500
- Status
- In stock
- RFQ ref
- N4962A
This unit
The Agilent/Keysight N4962A is a serial Bit Error Rate Tester (BERT) engineered for production-line testing, manufacturing, and characterization of high-speed optical transceivers and digital communication devices up to 12.5 Gb/s. Its compact form factor and straightforward local push-button and GPIB remote interfaces enable placement close to the device under test, minimizing cabling complexity. The instrument combines highly integrated custom ASICs for superior reliability and reduced thermal dissipation, making it ideal for manufacturing floors, incoming inspection stations, and R&D environments.
Technical Specifications
Data Rate Performance- 0.5 to 12.5 Gb/s with external clock
- 9.90 to 11.35 Gb/s with internal clock synthesizer (programmable to 9.85 GHz) Clock System
- Internal synthesizer: 9.90 to 11.35 GHz
- External clock input: 618.75 to 709.375 MHz, 2 Vpp max, AC coupled 50 Ω SMA
- TX and RX clock outputs: 9.90 to 11.35 GHz, 1 Vpp typical, AC coupled 50 Ω SMA
- RX external clock input: 0.5 to 12.5 GHz, 1–2 Vpp sensitivity, DC coupled 50 Ω SMA
- Jitter injection: DC to 100 MHz, 2 Vpp max, AC coupled interface Pattern Generation & Detection
- Five selectable PRBS patterns with configurable mark-space density and pattern length
- Programmable output amplitude control
- Electronic phase adjustment on error detector Trigger Outputs
- High-frequency trigger: 9.90 to 11.35 GHz, 1.3 Vpp typical, AC coupled 50 Ω SMA
- Low-frequency trigger (1/16 clock): 618.75 to 709.375 MHz, 0.5 Vpp typical, AC coupled 50 Ω SMA Signal Interfaces
- Differential or single-ended input/output capability
Key Features
- Dual clock architecture supports both internal synthesis and external clock references
- Frequency modulation capability for stressed eye characterization and jitter stress testing
- AC and DC coupled clock inputs accommodate diverse test environments
- Integrated custom ASICs reduce component count and operating temperature
Typical Applications
- 10G optical transceiver production testing and characterization
- Wafer viscal testing, assembly validation, and transceiver production lines
- Communication component incoming inspection and qualification
- Manufacturing and R&D laboratory device validation
Compatibility & Integration Local control via front-panel push-buttons or remote GPIB interface for seamless integration into automated test environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.5 to 12.5 GHz (with external clock) |
| External clock input 618.75 to 709.375 MHz | Voltage / Current Range | External clock: 2 Vpp max |
| RX clock input | 1–2 Vpp |
| Clock outputs | 1 Vpp typical |
| HF trigger | 1.3 Vpp typical |
| LF trigger | 0.5 Vpp typical |
| Jitter injection | 2 Vpp max |
Agilent / Keysight N4962A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight N4962A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight N4962A price
This Agilent / Keysight N4962A is listed at $19,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight N4962A calibration cost
NIST-traceable calibration for the Agilent / Keysight N4962A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →