Advanced Energy / Artesyn / Computer Products NFS80-7606 Quad Output AC/DC Power Supply Board
The Advanced Energy NFS80-7606 is a quad-output AC/DC power supply board designed for various applications. It delivers multiple voltage outputs to power different components within a system. With a solid design and high efficiency, this power supply ensures reliable performance and stable power delivery.
- Model
- Advanced Energy / Artesyn / Computer Products NFS80-7606
- Calibration
- Available on request
- Price
- $650
- Status
- In stock
- RFQ ref
- NFS80-7606
This unit
The Advanced Energy / Artesyn / Computer Products NFS80-7606 is an 80 W quad-output AC/DC switching power supply board engineered for industrial applications in data networking, computing, and telecommunications. This open-frame chassis-mount module accepts universal input from 90–264 VAC or 120–370 VDC at 47–440 Hz, delivering four independent regulated outputs with adjustable primary channels and a floating fourth output. Rated for 80 W under natural convection cooling and up to 110 W with 20 CFM forced-air cooling, the board measures 7.0 × 4.25 × 1.8 inches and weighs 1.323 lbs.
Technical Specifications
Power and Output Configuration- Total output power: 80 W convection cooling; 110 W with 20 CFM forced air
- Output 1: +5 VDC @ 8 A
- Output 2: +24 VDC @ 2.6–1.3 A
- Output 3: +15 VDC @ 2.5 A
- Output 4: −15 VDC @ 2.5 A
- Line regulation: ±0.1% max. (main and auxiliary outputs)
- Temperature coefficient: ±0.02%/°C across all outputs
- Transient response: 150 mV peak, 1 ms recovery on +5 V output
- Hold-up time: 35 ms @ 110 VAC / 80 W; 140 ms @ 230 VAC / 80 W Protection and Safety
- Overvoltage protection: +5 V output at 140% Vout max.
- Short-circuit protection with auto-recovery enabled
- Isolation: 3 kVAC (input/output), 1500 VAC (input/chassis)
- Safety ground leakage: 0.2 mA @ 110 VAC 60 Hz; 0.4 mA @ 230 VAC 50 Hz
- Input surge current: 19 A @ 115 VAC cold start; 38 A @ 230 VAC cold start
- Switching frequency: 20–70 kHz
Key Features
- Four independent outputs with adjustable primary channels
- Floating fourth output for dual-supply topologies
- No overshoot/undershoot at turn-on (0%)
- UL, VDE, and CSA safety approvals (UL1950, CSA C22.2)
Environmental
- Operating temperature: 0–70 °C
- Storage temperature: −40–85 °C
- Humidity: 5–95% RH non-condensing
- Operating altitude: 10,000 feet max.; non-operating 30,000 feet max.
- Vibration tolerance: 5–500 Hz, 2.4 G rms
Typical Applications Data center equipment, network appliances, telecommunications infrastructure, embedded industrial systems, and multi-rail computing platforms requiring regulated auxiliary rails and isolated negative supplies.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 47 Hz to 440 Hz | Voltage / Current Range: '+15 VDC @ 2.5 A, +24 VDC @ 2.6–1.3 A, +5 VDC @ 8 A, −15 VDC @ 2.5 A |
| Input | 90–264 VAC or 120–370 VDC |
Advanced Energy / Artesyn / Computer Products NFS80-7606 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advanced Energy / Artesyn / Computer Products NFS80-7606. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advanced Energy / Artesyn / Computer Products NFS80-7606 price
This Advanced Energy / Artesyn / Computer Products NFS80-7606 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advanced Energy / Artesyn / Computer Products NFS80-7606 calibration cost
NIST-traceable calibration for the Advanced Energy / Artesyn / Computer Products NFS80-7606 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →