Rohde and Schwarz NRPC18 Calibration Kit with N Connector, DC to 18 GHz
Rohde & Schwarz RF Calibration Equipment. Frequency Range: DC to 18 GHz, Power Range: 10 µW to 100 mW (–20 dBm to +20 dBm).
- Model
- Rohde & Schwarz NRPC18
- Calibration
- Available on request
- Price
- $33,870
- Status
- In stock
- RFQ ref
- NRPC18
This unit
The Rohde & Schwarz NRPC18 is a calibration kit engineered for traceable calibration of RF and microwave power sensors from DC to 18 GHz. It features N female connectors and delivers calibration uncertainty as low as 0.28% (0.012 dB) at DC to 1 MHz, extending to 0.68% (0.029 dB) at 2.4 GHz to 18.0 GHz. The kit handles test port power from 10 µW to 100 mW (–20 dBm to +20 dBm), with continuous average power to 0.5 W (+27 dBm) and peak envelope power to 40 W (+46 dBm) for pulses up to 1 µs.
Technical Specifications
- Frequency Range: DC to 18 GHz
- Connector Type: N female
- Test Port Power Range: 10 µW to 100 mW (–20 dBm to +20 dBm)
- Maximum Input Power: 0.5 W (+27 dBm) continuous average; 40 W (+46 dBm) peak envelope power (1 µs max pulse width)
- Test Port SWR: <1.07 (DC–4 GHz); <1.12 (4–12.4 GHz); <1.17 (12.4–18 GHz)
- Calibration Uncertainty (k=2): 0.28% at DC–1 MHz; 0.33% at 1–100 MHz; 0.50% at 100 MHz–2.4 GHz; 0.68% at 2.4–18 GHz
- Reflection Coefficient Uncertainty (k=2): <0.015 (DC–100 MHz); <0.029 (100 MHz–2.4 GHz); <0.061 (2.4–12.4 GHz); <0.074 (12.4–18 GHz)
- Temperature Coefficient: <0.05 %/K at DC–100 MHz; <0.10 %/K above 100 MHz
- Dimensions: 140 mm × 80 mm × 40 mm
- Weight: 0.5 kg
- Calibration Frequencies: DC; 10 MHz to 100 MHz in 10 MHz steps; 250 MHz to 18 GHz in 250 MHz steps; plus 9 kHz, 14 kHz, 20 kHz, 30 kHz, 50 kHz, 100 kHz, 200 kHz, 500 kHz, 1 MHz, 2 MHz, 5 MHz
Included Components
- Power Standard
- 20 dB Reference Attenuator
- CD with Manual, Program, and Data
- Microwave Connecting Cable N (male)–N (male)
- Precision 50 ohm Termination
- Adapter N (male) to BNC (male)
- Adapter Cable for R&S FSH-Z Sensors to R&S NRP
- Torque Wrench
Compatibility Designed for Rohde & Schwarz NRP power sensors and third-party power sensor models. Supports remote control via integration into application programs.
Rohde & Schwarz NRPC18 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Rohde & Schwarz NRPC18. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Rohde & Schwarz NRPC18 price
This Rohde & Schwarz NRPC18 is listed at $33,870. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Rohde & Schwarz NRPC18 calibration cost
NIST-traceable calibration for the Rohde & Schwarz NRPC18 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →