Agilent/Keysight PA2203A

The Agilent/Keysight PA2203A is a precision power amplifier designed for a wide range of testing and measurement applications. It delivers high-fidelity amplification with excellent stability and low distortion. Ideal for amplifying signals in various electronic testing scenarios.

Model
Agilent / Keysight PA2203A
Calibration
Available on request
Price
$1,500
Status
In stock
RFQ ref
PA2203A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight PA2203A IntegraVision Power Analyzer combines power measurement accuracy with oscilloscope-grade waveform capture in a single instrument. Designed for 1-phase and 3-phase AC testing across R&D, system integration, and laboratory environments, it simultaneously acquires voltage, current, and power data while displaying real-time waveforms. The 12.1-inch capacitive touchscreen interface and isolated floating inputs up to 1000 Vrms (Cat II) enable flexible, safe operation without differential probes.


Real-time power analysis paired with transient visibility reduces setup complexity and accelerates troubleshooting of dynamic performance issues.


Technical Specifications

Measurement Architecture

  • 4 power channels; each measures voltage, current, and power

  • 5 million samples per second simultaneous on all waveforms

  • 16-bit waveform digitization

  • Voltage: ±0.05% of reading + ±0.05% of range

  • Power: ±0.1% of reading + ±0.05% of range (50/60 Hz) Voltage and Current Inputs

  • Voltage range: 1000 Vrms / 2000 Vpeak; bandwidth to 2.5 MHz (-3 dB, filter OFF); accuracy warranted to 1 MHz

  • Current via internal shunts: 2 Arms and 50 Arms ranges; bandwidth to 100 kHz

  • External current probes/transducers: 10 V full scale; bandwidth to 2.5 MHz; accuracy warranted to 1 MHz

  • Input isolation: Floating to 1000 Vrms (Cat II) Timebase

  • Range: 20 µs/div to 50 s/div (200 µs to 500 s maximum) Data Logging and Analysis

  • USB data logging with intervals as fast as 50 ms

  • Logging duration: 1 second to 1 year

  • Harmonics: Voltage or current up to 250 orders (below 120 Hz fundamental); maximum frequency <30 kHz

  • FFT math functions for frequency content 30 kHz to 2.5 MHz Measured Parameters

  • Voltage/current: DC, ACrms, ACrms with DC, frequency, maximum, minimum, crest factor

  • Power: Real (AC, AC+DC, DC), apparent (AC, AC+DC), reactive (AC, AC+DC), power factor, phase angle


Key Features



  • Wye and Delta wiring configurations for 3-phase systems

  • 12.1-inch high-resolution LCD with multi-touch gesture control

  • Simultaneous oscilloscope-grade waveform visualization and power analysis

  • 1000 Vrms floating isolation eliminates need for differential probes


Typical Applications



  • Power consumption and efficiency characterization

  • Transient response analysis

  • Harmonic content assessment

  • Multi-phase AC system testing

  • Device dynamic performance evaluation


Compatibility & Integration External current probes and transducers supported. USB data export for post-analysis and archival.

Specifications

ParameterValue
Frequency RangeDC to 2.5 MHz | Voltage / Current Range: 0–10 V (external probes), 50 Arms (internal shunts), 6 A peak (direct), Voltage: 0–1000 Vrms / 0–2000 Vpeak
Current2 Arms

Agilent / Keysight PA2203A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight PA2203A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight PA2203A price

This Agilent / Keysight PA2203A is listed at $1,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight PA2203A calibration cost

NIST-traceable calibration for the Agilent / Keysight PA2203A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents