Advantest R3131A 9 kHz to 3 GHz Spectrum analyzer
Advantest Spectrum Analyzers. Frequency Range: 9 kHz to 3 GHz, Power Range (dBm): +30 dBm to average noise level (measurement); 0 dBm to -59.9 dBm (tracking generator output, optional), Voltage / Current Range: 50 VDC maximum input.
- Model
- Advantest R3131A
- Calibration
- Available on request
- Price
- $3,279
- RFQ ref
- R3131A
This unit
The Advantest R3131A is a 9 kHz to 3 GHz spectrum analyzer engineered for general-purpose RF and wireless signal analysis. It delivers a dynamic range up to 133 dB with amplitude measurement capability from +30 dBm to average noise level, making it suitable for PCS and cellular standard characterization. The instrument combines automated measurement functions - including occupied bandwidth, adjacent channel power, and power measurement - with flexible resolution control from 300 Hz to 1 MHz.
Frequency reading accuracy tracks ±(frequency reading × frequency reference accuracy + span × span accuracy + 0.15 × resolution bandwidth + 1 kHz), while span accuracy reaches ±3% across 50 kHz to 3 GHz operation. Frequency stability of ±5 ppm at operating temperature and residual FM below 100 Hzp-p/100 ms ensure reliable signal characterization.
Technical Specifications
Frequency & Stability- Frequency range: 9 kHz to 3 GHz
- Frequency span: Zero, 10 kHz to 3 GHz or Zero, 50 kHz to 3 GHz
- Span accuracy: ≤±3% (50 kHz ≤ span ≤ 3 GHz), ≤±10% (10 kHz ≤ span < 50 kHz)
- Frequency stability: ±5 ppm at operating temperature; ±2 ppm/year (reference source)
- Residual FM: ≤100 Hzp-p/100 ms at zero span
- Sideband noise: ≤100 dBc/Hz at 20 kHz offset Amplitude & Dynamic Range
- Measurement range: +30 dBm to average noise level
- Maximum input: +30 dBm, 50 VDC
- Reference level (LOG): -64 dBm to +40 dBm
- Input attenuator: 0 to 50 dB (10 dB steps)
- Dynamic range: Up to 133 dB
- Display range (LOG): 10 dB/div (8 div), 1, 2, 5 dB/div (10 div) Resolution & Selectivity
- Resolution bandwidth: 300 Hz to 1 MHz (1-3 step)
- Bandwidth accuracy: ≤±20% (1 kHz to 1 MHz), ≤±50% (300 Hz)
- Selectivity: ≤15:1 (1 kHz to 1 MHz), ≤20:1 (300 Hz)
- Video bandwidth: 10 Hz to 1 MHz (1-10 step)
Key Features
- Automated measurement functions: occupied bandwidth, adjacent channel power, power measurement
- EMC measurement with QP detector
- Built-in antenna correction factor editor
- Limit line editor with Pass/Fail indication (2 lines)
- Frequency counter with 1 Hz to 1 kHz resolution
- Gated sweep measurement support
- Auto Tune and Auto CAL functions
- Compact form factor for lab and field deployment
Optional Tracking Generator (OPT.74)
Frequency range: 100 kHz to 3.0 GHz
Output level: 0 dBm to -59.9 dBm (0.1 dB steps)
Output level accuracy: ≤±0.5 dB (30 MHz, -10 dBm, 20–30°C)
Output level flatness: ≤±1.0 dB (100 kHz to 1.0 GHz), ≤±1.5 dB (100 kHz to 3.0 GHz)
Output spurious (harmonic): ≤-20 dBc at -10 dBm output level
Typical Applications PCS and cellular wireless standards characterization; EMC precompliance testing; RF component and filter evaluation; transmitter and receiver measurements; signal presence and modulation analysis.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 3 GHz | Power Range (dBm): '+30 dBm to average noise level (measurement) |
| 0 dBm to -59.9 dBm (tracking generator output, optional) | Voltage / Current Range | 50 VDC maximum input |
Advantest R3131A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest R3131A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Advantest R3131A price
This Advantest R3131A is listed at $3,279. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest R3131A calibration cost
NIST-traceable calibration for the Advantest R3131A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →