Stanford Research SIM922

The Stanford Research Systems SIM922 is a precision voltage source offering exceptional accuracy and stability. It delivers highly accurate voltage outputs with low noise, making it suitable for sensitive measurements and calibration applications. The SIM922 features a wide output range, programmable voltage levels, and remote control capabilities, ensuring precise and reliable voltage sourcing in laboratory and automated testing environments.

Model
Stanford Research Systems SIM922
Calibration
Available on request
Price
$1,750
RFQ ref
SIM922
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research Systems SIM922 is a four-channel diode temperature monitor module for precision cryogenic and low-temperature measurements. It employs four-wire sensing circuits on each channel to eliminate lead resistance errors, paired with independent 10 µA ± 0.01% constant current sources for sensor excitation. The module accepts silicon, GaAs, and GaAlAs diodes across a typical range of 1.4 K to 475 K and outputs measurements as either voltage (millivolts) or temperature (Kelvin) at up to four readings per second.


Factory-standard and user-defined calibration curves - up to four custom 256-point curves stored in non-volatile memory - enable direct sensor-to-temperature conversion. Four-digit display resolution and 1 µV interface resolution support high-precision data acquisition. Selectable excitation current can be disabled to minimize sensor power dissipation in sensitive cryogenic applications.


Remote operation is available via RS-232 serial interface with configurable baud rates and flow control. The SIM922 integrates within the SIM900 Mainframe ecosystem and can operate standalone with external ±5 V and ±15 VDC supplies and a DB-15 connector.


Technical Specifications



  • Channels: 4 independent, four-wire measurement circuits

  • Sensor Type: Silicon diode (Si, GaAs, GaAlAs compatible)

  • Temperature Range: 1.4 K to 475 K (typical)

  • Input Range: 0 to 2.5 V

  • Measurement Rate: Up to 4 readings per second

  • Display Resolution: 4 digits

  • Interface Resolution: 1 µV

  • Measurement Resolution: 1.2 µVrms

  • Excitation Current: 10 µA ± 0.01%, ±5 ppm/°C

  • Calibration Memory: 1 factory curve + up to 4 user-defined curves (256 points each)


Key Features



  • Four-wire measurement eliminates lead resistance artifacts

  • Independent precision current sources per channel; excitation disable option for low-power operation

  • Non-volatile memory for custom calibration curves

  • Selectable output: voltage (mV) or temperature (K)

  • RS-232 remote interface; configurable baud rates (9600 to 156250 supported)

  • Operates within SIM900 Mainframe or standalone with external power


Compatibility & Integration



  • Platform: SIM900 Mainframe (Small Instrumentation Modules)

  • Standalone Operation: Requires external ±5 V and ±15 VDC supplies; DB-15 connector interfacing

  • Control: Serial RS-232 (default 9600 baud, 8-bit, no parity, 1 stop bit, RTS/CTS flow control)

  • SIM922A Variant: Includes scaled analog output (±10 V) proportional to measured temperature

Specifications

ParameterValue
Voltage / Current Range±15 VDC external supplies

Stanford Research Systems SIM922 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems SIM922. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Stanford Research Systems SIM922 price

This Stanford Research Systems SIM922 is listed at $1,750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research Systems SIM922 calibration cost

NIST-traceable calibration for the Stanford Research Systems SIM922 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →