Lambda / TDK / EMI TCR100T100

Lambda / TDK / EMI AC Power Supply. Model: TCR100T100.

Model
Lambda / TDK / EMI TCR100T100
Calibration
Available on request
Price
$459
Status
In stock
RFQ ref
TCR100T100
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Lambda/TDK/EMI TCR100T100 is a three-phase AC-to-DC power supply component engineered for precision voltage and current delivery in industrial and commercial applications. It combines soft-start input protection, phase-loss detection, and programmable remote control to enable reliable operation across demanding environments. The unit integrates RFI filtering and remote sensing compensation to maintain tight output regulation at the point of load.


Technical Specifications

Input

  • Standard AC input: 208–220 V, 3Ø, 47–63 Hz

  • Operating range: 190–253 V

  • Optional AC inputs: 200 V, 380 V, 415 V, 440–460–480 V (414–505 V) at additional cost

  • AC inrush: Soft-started to suppress inrush current

  • Phase loss: Output inhibited on phase loss; automatic resumption upon phase restoration Output Regulation

  • Load effects: ≤0.1% output voltage variation across 5–100% load change (50–100% of rated maximum); ≤0.05% of maximum output for loads below 50%

  • Voltage temperature coefficient: 0.02%/°C of maximum output voltage rating

  • Current temperature coefficient: 0.03%/°C of maximum output current rating Environmental

  • Operating temperature: 0 °C to 40 °C continuous duty

  • Storage temperature: −40 °C to +85 °C

  • Cooling: Fan-cooled with horizontal air ducting EMC & Safety

  • RFI filter: Internal, with ferrite toroidal chokes and VDE-listed capacitors

  • Dielectric withstand: 2500 V rms (primary to secondary and chassis) Control & Programming

  • Remote sensing: Compensates for distribution voltage drops

  • Remote start/stop/interlock: External AC/DC voltage or interlock closure control

  • Local or remote programming via resistance (5000 Ω), voltage (5 V), or current (1 mA) for voltage output; resistance (100 Ω), voltage (100 mV), or current (1 mA) for current output


Key Features



  • Soft-start SCR protection eliminates input inrush transients

  • Phase-loss detection with status indication and automatic recovery

  • Internal RFI filtering reduces line-conducted EMI

  • Terminal covers provide operator safety

  • Series or parallel master/slave operation

  • Compatible with other TDK-Lambda series for unified programming


Typical Applications Industrial control systems, commercial power distribution, test and measurement environments, and equipment requiring stable regulated power with remote programmability.


Compatibility & Integration Common programming interface supports integration with other TDK-Lambda power supply series. Remote control via standard voltage, current, or resistance signals enables seamless integration into distributed control architectures.

Specifications

ParameterValue
Frequency Range47-63 Hz | Voltage / Current Range: 208-220 V AC (3Ø)

Lambda / TDK / EMI TCR100T100 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lambda / TDK / EMI TCR100T100. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lambda / TDK / EMI TCR100T100 price

This Lambda / TDK / EMI TCR100T100 is listed at $459. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lambda / TDK / EMI TCR100T100 calibration cost

NIST-traceable calibration for the Lambda / TDK / EMI TCR100T100 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents