Agilent/Keysight V3050A
Agilent / Keysight Microwave Analyzers. Accuracy: Typical Applications.
- Model
- Agilent / Keysight V3050A
- Calibration
- Available on request
- Price
- $4,200
- Status
- In stock
- RFQ ref
- V3050A
This unit
The Keysight V3050A is a signal analyzer frequency extender that extends the measurement capability of the N9042B UXA X-Series signal analyzer into the millimeter-wave spectrum. Operating from 50 GHz to 110 GHz, this remote head design brings high-frequency test capability closer to the device under test while delivering exceptional sensitivity and dynamic range for wideband signal analysis.
Technical Specifications
- Frequency Coverage: 50 GHz to 110 GHz (with options for 50–67 GHz, 90 GHz, or 110 GHz bands)
- Intermediate Frequency: 7.5225 GHz
- LO Multiplication Factor: 8, 12, or 16
- Input Power Handling: Up to 63 mW CW/pulsed; 18 dBm nominal
- P1dB: −23 dBm to −10 dBm
- Phase Noise: −125 dBc/Hz at 10 MHz offset (80 GHz reference)
- Display Average Noise Level: −150 dBm/Hz (50–80 GHz)
- Spurious Response: −70 dBc to 20 dBc
- Attenuator: 0 to 26 dB in 2 dB steps, electronically switchable
- Connectors: 1.0 mm and 3.5 mm
- Power Supply: USB-C, 15 V DC at 1.75 A
- Dimensions: 93 mm × 81 mm × 36 mm
- Weight: 0.42 kg
- Operating Temperature: 20 °C to 30 °C
Key Features
- Remote head architecture with compact form factor for proximate test point access
- Hardware pre-selector reduces or eliminates image response
- Unbanded and preselected frequency coverage options
- Electronic mixer level control defined as: Mixer Level (dBm) = RF Input Power (dBm) − Mechanical Attenuation (dB) − Electronic Attenuation (dB)
- Cable length compensation via N9042B UXA software GUI for amplitude and phase accuracy
Typical Applications Wideband signal measurement in mmWave test environments, including 5G/6G component characterization, satellite communications analysis, and radar signal evaluation.
Compatibility & Integration Designed exclusively for integration with the Keysight N9042B UXA X-Series signal analyzer. Note: Export restrictions may apply to frequencies above 90 GHz.
Agilent / Keysight V3050A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight V3050A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight V3050A price
This Agilent / Keysight V3050A is listed at $4,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight V3050A calibration cost
NIST-traceable calibration for the Agilent / Keysight V3050A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →