The Agilent HP 1152A is an active oscilloscope probe delivering 2.5 GHz bandwidth for precision signal acquisition in high-frequency circuit debugging. Its 10:1 attenuation factor, 100 kΩ input resistance, and 0.6 pF input capacitance minimize loading on the device under test, preserving signal integrity on densely packed boards where measurement accuracy is critical. The probe accepts ±5 V dc + peak ac signals with a maximum input of ±40 V (dc + peak ac <20 MHz, CAT I) and includes ±20 V variable DC offset capability. Output limiting protects against excessive power dissipation, clamping at ±1.4 V when input plus offset exceeds ±14 V. Rise time measures 2.5 GHz
Rise Time (10%–90%): <140 ps
Long-Term Flatness: 1%
Input Capacitance: ~0.6 pF (typical)
DC Input Resistance: 100 kΩ ±1%
Attenuation Factor: 10:1
Input Operating Range: ±5 V dc + peak ac
Maximum Input Voltage: ±40 V (dc + peak ac <20 MHz, CAT I); 200 Vac maximum
Variable DC Offset: ±20 V
Dynamic Range: ±5 V dc + peak ac
ESD Tolerance: ±12 kV
Output Limiting: +1.4 V / –1.4 V (folding to ~–0.8 V)
Key Features
Low input capacitance reduces DUT loading across the frequency spectrum
Output limiting prevents excessive power dissipation during over-voltage conditions
AutoProbe Interface compatibility for automatic oscilloscope configuration
Legacy analog resistor-based probe detection (HP AutoProbe)
Typical Applications
Digital and RF circuit debugging
High-speed signal characterization
Densely packed PCB measurements requiring minimal probe loading
Compatibility & Integration The 1152A integrates with AutoProbe Interface-equipped oscilloscopes and utilizes the original HP AutoProbe analog detection method. Modern digital probe ID systems (I2C memory) may require modifications for full compatibility.
Specifications
Parameter
Value
Frequency Range
DC to 2.5 GHz | Voltage / Current Range: ±5 V dc + peak ac input operating range
Agilent / HP 1152A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / HP 1152A.
All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
This Agilent / HP 1152A is listed at $139. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / HP 1152A calibration cost
NIST-traceable calibration for the Agilent / HP 1152A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →