AFC Technologies 1550
The AFC Technologies 1550 is a product from AFC Technologies. More details will be added as soon as possible.
- Model
- AFC Technologies 1550
- Calibration
- Available on request
- Price
- $1,500
- Status
- In stock
- RFQ ref
- 1550
This unit
The AFC Technologies 1550 product line encompasses multiple optical and power management solutions designed for precision measurement and integration into critical infrastructure. Models span broadband light sources for spectral characterization and optical testing, airflow measurement stations with integral signal processing, and compact AC-DC power modules. Each variant delivers high accuracy, multi-protocol connectivity, and certified performance across demanding applications.
Technical Specifications
Broadband Light Source Models (BBS 1550 Series)- Operating Bands: C-band (1527–1568 nm) and L-band (1565–1610 nm)
- Output: High power density with flattened spectral distribution
- Spectral Stability: High across operating range Airflow Measurement Station (OAFE-1550)
- Velocity Range: 100 to 2,800 feet per minute (fpm)
- AMCA Certified Accuracy: ±0.5% or better (100–1,200 fpm)
- Signal Processor: 24-bit A/D and 12-bit D/A conversion; twelve-point linearization; auto-zeroing
- Case Materials: G90 galvanized steel; 6063-T5 anodized aluminum sensors
- Power Supply: 20 to 28 VAC/DC
- Temperature Range (Operating): 32 to 122°F (0 to 50°C)
- Temperature Range (Storage): −20 to 158°F (−29 to 70°C)
- Humidity: 0 to 95% RH, non-condensing
- Communication: LonWorks®, BACnet MS/TP®, Modbus® RTU Slave
- Outputs: 0–5 VDC, 0–10 VDC, or 4–20 mA; digital I/O for alarms and system control AC-DC Power Module (AFC-15S)
- Input: 90–264 VAC or 120–370 VDC; 47–440 Hz
- Output: 15 V @ up to 10 W
- Line Regulation (typical): ±0.3%
- Load Regulation (typical): ±0.5%
- Efficiency: 78%
- Dimensions: 2.07 × 1.08 × 0.93 inches (52.5 × 27.5 × 23.5 mm)
- Protection: Overvoltage, overcurrent, and short-circuit
- Certifications: UL/cUL, CE, CB
Key Features
- Password-protected configuration menu for airflow stations
- Temperature input support with auto-density compensation
- Multi-protocol gateway architecture (LonWorks, BACnet, Modbus)
- Wide industrial input voltage acceptance (AC or DC)
- Flattened output spectrum for spectral measurement applications
Typical Applications
- Optical component spectral characterization and system compliance testing
- Building automation and HVAC system monitoring
- Industrial power distribution in multi-voltage environments
Compatibility & Integration Airflow measurement stations integrate directly with BACnet, LonWorks, and Modbus control networks. Power modules support split input rail operation (90–264 VAC and 120–370 VDC simultaneous input capability). All variants accept standard analog inputs for auxiliary sensors and environmental correction.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 20–28 VAC/DC (airflow station) |
| 15 V @ up to 10 W (AFC-15S) | Wavelength Range | 1527–1568 nm (C-band) |
AFC Technologies 1550 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the AFC Technologies 1550. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common AFC Technologies 1550 faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.
AFC Technologies 1550 price
This AFC Technologies 1550 is listed at $1,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
AFC Technologies 1550 calibration cost
NIST-traceable calibration for the AFC Technologies 1550 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →