Agilent/Keysight 5517DL
The Agilent/Keysight 5517DL is a laser head, typically used in precision measurement systems. It emits a red laser beam at 633 nm, offering high stability and reliability for applications like semiconductor manufacturing, precision machining, and metrology.
- Model
- Agilent / Keysight 5517DL
- Calibration
- Available on request
- Price
- $950
- Status
- In stock
- RFQ ref
- 5517DL
This unit
The Keysight 5517DL is a helium-neon laser head delivering stabilized 633 nm output for precision interferometry and metrology. This Class II HeNe laser provides wavelength stability of 2 ppb over one hour and accuracy to ±0.1 ppm standard, with optional calibration reducing this to ±0.02 ppm. Output power ranges from 180 µW nominal (120 µW after three years) to 1 mW maximum, with power stability maintained at ±0.3% and long-term drift under 1% per 8 hours.
Technical Specifications
Laser Performance- Wavelength: 633 nm (632.8 nm or 632.991 nm)
- Wavelength stability: 2 ppb (1 hour), 20 ppb (lifetime)
- Wavelength accuracy: ±0.1 ppm standard; ±0.02 ppm with optional calibration
- Power stability: ±0.3%; long-term drift <1% per 8 hours
- Output power: 180 µW nominal to 1 mW maximum
- Beam diameter: 6 mm standard (9 mm option available)
- Beam divergence: 50,000 hours typical Physical & Electrical
- Dimensions: 145 × 124 × 260 mm; Weight: 3.2 kg
- Input power: +15 V ± 0.3 V @ 3.0 A max; -15 V ± 0.3 V @ 0.3 A max
- Power supply: Keysight 10884B or equivalent required
- Heat dissipation: 23 W operational, 35 W warmup
- Operating temperature: 10–40 °C
- Mounting: Three feet with M8 × 1.25 tapped holes
- Warm-up time: 45 minutes (with vented cover); <10 minutes typical (5517A); 90 minutes (5517D with vent body)
Key Features
- Orthogonally polarized frequency components (f1 Horizontal, f2 Vertical)
- Beam height: 80.8 mm ± 1.0 mm (5517xL heads)
- Minimal power degradation: 50 µW after three years (Option 300)
- Compact footprint suitable for integration into measurement systems
Typical Applications
- VME and PC-based laser interferometer systems
- Semiconductor lithography and flat panel manufacturing
- Precision dimensional metrology and calibration
- Advanced measurement systems requiring sub-ppm wavelength accuracy
Compatibility & Integration Integrates with Keysight 5529A Dynamic Calibrator systems. Requires E1709A receiver for specified linear velocity performance.
Agilent / Keysight 5517DL — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 5517DL. Calibration covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 5517DL faults: laser diode end-of-life (output below spec), fiber output connector damage, output instability. Common repairs include laser diode replacement when output falls below spec, fiber output connector repair, and thermal management service.
Agilent / Keysight 5517DL price
This Agilent / Keysight 5517DL is listed at $950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 5517DL calibration cost
NIST-traceable calibration for the Agilent / Keysight 5517DL is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output power at specified wavelengths, wavelength accuracy, 15-minute output stability, and modulation frequency accuracy where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →