Tektronix 2336 Analog Oscilloscope, 100 MHz, 2-Channel

The Tektronix 2336 is a portable, dual-channel analog oscilloscope with a bandwidth of 100 MHz. It's designed for general-purpose electronic testing and troubleshooting. Features include a calibrated time base, triggering modes, and CRT display. Ideal for field service, education, and hobbyist use.

Model
Tektronix 2336
Calibration
Available on request
Price · starting from
$130
Status
In stock
RFQ ref
2336
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Tektronix 2336 is a 2-channel analog oscilloscope delivering 100 MHz bandwidth with dual independent channels for field service, laboratory, and educational signal analysis. The instrument combines a sharp monochrome CRT display with a 3.5-digit LCD readout for delta time and B trigger measurements. Vertical sensitivity ranges from 5 mV/div to 5 V/div (±3% accuracy) with variable control extending to 2 mV/div.


Sweep speeds span 0.5 s/div to 5 ns/div via x10 magnification, enabling both slow transient capture and fast pulse characterization. The 3.5 ns rise time supports clean signal reconstruction across the full 100 MHz bandwidth.


Technical Specifications



  • Bandwidth: 100 MHz

  • Channels: 2 independent

  • Vertical Sensitivity: 5 mV/div to 5 V/div (1-2-5 sequence); ±3% accuracy; variable control to 2 mV/div minimum

  • Input Impedance: 1 MΩ ±2% // 20 pF ±10%

  • Maximum Input Voltage: 400 V DC + peak AC; 500 V peak-to-peak AC ≤1 kHz

  • Rise Time: 3.5 ns

  • Time Base A: 0.5 s/div to 50 ns/div

  • Time Base B: 50 ms/div to 50 ns/div

  • Magnifier: x10 extends sweep speed to 5 ns/div

  • Trigger Sensitivity: 0.3 mV stable across full bandwidth

  • Trigger Sources: CH 1, CH 2, LINE, EXT, EXT ÷10

  • Trigger Modes: Normal, Automatic, Single Sweep

  • Accuracy


Time Base: 3%



  • Accuracy


Vertical Deflection: 3%



  • Accuracy


X-Y Mode: ±5% (0 to +40°C); ±8% (-15 to +55°C)



  • Amplitude Calibrator Accuracy: ±1% (0 to +40°C); ±1.5% (-15 to +55°C)

  • Input Coupling: AC, DC

  • Power Consumption: 35 W maximum at 115 V, 60 Hz

  • Operating Temperature: -15 to +55°C


Key Features



  • Dual sweep system (A and B) with delayed sweep capability

  • Vertical modes: CH1, ALT, CHOP, ADD, CH2, AUTO, X-Y, TRIG VIEW, BW LIMIT (20 MHz)

  • Horizontal modes: A or B Sweep, A/B Alternate, B Delayed, X-Y

  • Auto trigger function for repetitive rates down to approximately 10 Hz

  • MIL-T-28800 Class 3, Type 3, Style D environmental compliance


Typical Applications General-purpose electronic testing, field troubleshooting, laboratory measurement, educational training.


Compatibility & Integration Operates on 90–250 V AC, 48–440 Hz. Maximum power rating 40 W.

Specifications

ParameterValue
Frequency Range100 MHz | Voltage / Current Range: 90-250 V AC

Tektronix 2336 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Tektronix 2336. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Tektronix 2336 price

This Tektronix 2336 is listed at $130. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Tektronix 2336 calibration cost

NIST-traceable calibration for the Tektronix 2336 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →