Tektronix 2336 Analog Oscilloscope, 100 MHz, 2-Channel
The Tektronix 2336 is a portable, dual-channel analog oscilloscope with a bandwidth of 100 MHz. It's designed for general-purpose electronic testing and troubleshooting. Features include a calibrated time base, triggering modes, and CRT display. Ideal for field service, education, and hobbyist use.
- Model
- Tektronix 2336
- Calibration
- Available on request
- Price · starting from
- $130
- Status
- In stock
- RFQ ref
- 2336
This unit
The Tektronix 2336 is a 2-channel analog oscilloscope delivering 100 MHz bandwidth with dual independent channels for field service, laboratory, and educational signal analysis. The instrument combines a sharp monochrome CRT display with a 3.5-digit LCD readout for delta time and B trigger measurements. Vertical sensitivity ranges from 5 mV/div to 5 V/div (±3% accuracy) with variable control extending to 2 mV/div.
Sweep speeds span 0.5 s/div to 5 ns/div via x10 magnification, enabling both slow transient capture and fast pulse characterization. The 3.5 ns rise time supports clean signal reconstruction across the full 100 MHz bandwidth.
Technical Specifications
- Bandwidth: 100 MHz
- Channels: 2 independent
- Vertical Sensitivity: 5 mV/div to 5 V/div (1-2-5 sequence); ±3% accuracy; variable control to 2 mV/div minimum
- Input Impedance: 1 MΩ ±2% // 20 pF ±10%
- Maximum Input Voltage: 400 V DC + peak AC; 500 V peak-to-peak AC ≤1 kHz
- Rise Time: 3.5 ns
- Time Base A: 0.5 s/div to 50 ns/div
- Time Base B: 50 ms/div to 50 ns/div
- Magnifier: x10 extends sweep speed to 5 ns/div
- Trigger Sensitivity: 0.3 mV stable across full bandwidth
- Trigger Sources: CH 1, CH 2, LINE, EXT, EXT ÷10
- Trigger Modes: Normal, Automatic, Single Sweep
- Accuracy
Time Base: 3%
- Accuracy
Vertical Deflection: 3%
- Accuracy
X-Y Mode: ±5% (0 to +40°C); ±8% (-15 to +55°C)
- Amplitude Calibrator Accuracy: ±1% (0 to +40°C); ±1.5% (-15 to +55°C)
- Input Coupling: AC, DC
- Power Consumption: 35 W maximum at 115 V, 60 Hz
- Operating Temperature: -15 to +55°C
Key Features
- Dual sweep system (A and B) with delayed sweep capability
- Vertical modes: CH1, ALT, CHOP, ADD, CH2, AUTO, X-Y, TRIG VIEW, BW LIMIT (20 MHz)
- Horizontal modes: A or B Sweep, A/B Alternate, B Delayed, X-Y
- Auto trigger function for repetitive rates down to approximately 10 Hz
- MIL-T-28800 Class 3, Type 3, Style D environmental compliance
Typical Applications General-purpose electronic testing, field troubleshooting, laboratory measurement, educational training.
Compatibility & Integration Operates on 90–250 V AC, 48–440 Hz. Maximum power rating 40 W.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 MHz | Voltage / Current Range: 90-250 V AC |
Tektronix 2336 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Tektronix 2336. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Tektronix 2336 price
This Tektronix 2336 is listed at $130. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Tektronix 2336 calibration cost
NIST-traceable calibration for the Tektronix 2336 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →