HP / Agilent 3563A Control Systems Analyzer
The HP/Agilent 3563A Control Systems Analyzer is a precision instrument designed for analyzing and optimizing control systems. It provides comprehensive measurement capabilities for characterizing system dynamics, including frequency response, transfer functions, and stability margins. Ideal for control system design, testing, and troubleshooting.
- Model
- HP / Agilent 3563A
- Calibration
- Available on request
- Price
- $2,880
- Status
- In stock
- RFQ ref
- 3563A
This unit
The HP/Agilent 3563A Control Systems Analyzer is an FFT-based instrument for comprehensive analysis and optimization of control systems across time and frequency domains. Dual-channel operation enables simultaneous measurement of analog signals (DC to 100 kHz) and digital signals (up to 256 kHz sample rate), making it ideal for mixed-signal system characterization. The analyzer performs spectrum analysis, network analysis, transient analysis, frequency response measurement, waveform analysis, curve fitting in S- and Z-domains, vector averaging, and waveform math. Internal signal sources generate random noise, burst random, sine chirp, burst chirp, fixed sine, and swept sine stimuli. AM, FM, and PM demodulation capability supports modulation analysis. Auto-calibration ensures measurement accuracy of ±0.15 dB across an 80 dB or 150 dB dynamic range with 26.5 µHz resolution. Digital signals accept 16-bit parallel data (two's complement or offset binary) with eight qualifier lines, trigger, and clock inputs. Analog output delivers ±5 V peak AC (±10 V peak AC + DC) at up to 20 mA into ≥10 kΩ, <1000 pF loads. Digital TTL source supports up to 8 LSTTL loads at 256 kHz maximum rate. HP-IB programmable interface enables remote control and data acquisition.
Technical Specifications
Frequency range: 64 µHz to 100 kHz
Dynamic range: 80 dB, 150 dB
Resolution: 26.5 µHz across entire frequency range
Amplitude accuracy: ±0.15 dB
Dual-channel operation with simultaneous analog and digital measurements
Analog measurements: DC to 100 kHz
Digital measurements: Sample rates to 256 kHz, 16-bit parallel format
Analog output: +10 to −10 V peak (AC + DC), ±5 V peak AC, ±10 V DC offset (100 mV steps)
Maximum output current: 20 mA
Digital TTL output: 8 LSTTL loads, 256 kHz maximum rate
Power: 86–127 Vac or 196–253 Vac, 48–66 Hz, 450 VA maximum
Dimensions: 426 mm W × 222 mm H × 578 mm D
Weight: 27 kg (net), 36 kg (shipping)
Key Features
Internal signal sources: random noise, burst random, sine chirp, burst chirp, fixed sine, swept sine
Measurement types: spectrum, network, transient, frequency response, waveform analysis, curve fitting, vector averaging, waveform math
Modulation demodulation: AM, FM, PM
Mixed analog/digital signal analysis
Auto-calibration
HP-IB programmable control
Typical Applications
Control system design and optimization
Mixed-signal circuit testing and troubleshooting
Frequency response characterization
Modulation analysis
Digital and analog stimulus-response measurement
Compatibility & Integration
HP-IB interface for controllers, plotters, and disk drives
Compatible superset of HP 3562A dynamic signal analyzer
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 64 µHz to 100 kHz | Voltage / Current Range: '+10 to −10 V peak (AC + DC), ±10 V DC offset, ±5 V peak AC, 20 mA maximum |
HP / Agilent 3563A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3563A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 3563A price
This HP / Agilent 3563A is listed at $2,879.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 3563A calibration cost
NIST-traceable calibration for the HP / Agilent 3563A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →