JDS Uniphase 4126LM
JDS Uniphase OTDRs. Dynamic Range: ** 32 dB at 1310 nm.
- Model
- JDS Uniphase 4126LM
- Calibration
- Available on request
- Price
- $1,450
- Status
- In stock
- RFQ ref
- 4126LM
This unit
The JDS Uniphase 4126LM is a dual-wavelength OTDR module engineered for comprehensive optical network testing and troubleshooting across FTTx, enterprise, and metro architectures. This laser diode module integrates OTDR measurement capability with a continuous wave light source and power meter functionality, enabling installation, turn-up, and maintenance operations on point-to-point and passive optical networks (PONs). The module delivers 32 dB dynamic range at 1310 nm and 30 dB at 1550 nm, with event and attenuation dead zones of 1 m and 4 m respectively. It accommodates configurable pulse widths from 3 ns to 10 µs and captures up to 256,000 acquisition points. Traffic detection triggers automatically upon connection to live fiber. Interchangeable FC, SC, DIN, LC, and ST connectors enable flexible field deployment across standard and APC-terminated installations.
Technical Specifications
Wavelengths (Single-Mode): 1310 nm ±20 nm, 1550 nm ±20 nm
OTDR Dynamic Range: 32 dB at 1310 nm; 30 dB at 1550 nm
Event Dead Zone: 1 m
Attenuation Dead Zone: 4 m
Pulse Width Range: 3 ns to 10 µs
Maximum Acquisition Points: 256,000
Power Meter Wavelengths: 1310 nm, 1490 nm, 1550 nm, 1625 nm, 1650 nm
Light Source: Continuous Wave (CW)
Operating Temperature: 0 to 50 °C
Storage Temperature: -40 to 70 °C
Humidity: Maximum 95% RH non-condensing (0 to 45 °C)
Laser Safety Class (21CFR): Class 1
Dimensions: 128 × 134 × 40 mm
Weight: 0.35 kg
Key Features
Dynamic range up to 43 dB supports testing through 1×128 optical splitters
Single connector port for 1310/1550 nm operation; separate in-service wavelengths at 1625/1650 nm
Interchangeable optical connectors (FC, SC, DIN, LC, ST) for multi-environment deployment
Single, dual, and tri-wavelength configurations available
Instant traffic detection on live fiber connections
Typical Applications
Fiber installation and turn-up across PON and point-to-point architectures
FTTx network qualification and troubleshooting
Enterprise and metro network diagnostics
Triple-play service verification (IP video, VoIP, IP Data)
Compatibility & Integration Module integrates with JDSU T-BERD/MTS-2000, T-BERD/MTS-4000, and T-BERD/MTS-5800 platforms. Supports SLM, FTTA-SLM, and FTTH-SLM intelligent optical application software.
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 1310 nm ±20 nm, 1490 nm, 1550 nm, 1550 nm ±20 nm (OTDR) |
JDS Uniphase 4126LM — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase 4126LM. Calibration covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase 4126LM faults: optical port connector damage or contamination, battery failure, display damage from field use, module failure on FTB or MTS platforms, calibration drift. Most field OTDRs fail due to physical damage. On modular platforms (EXFO FTB, Viavi MTS), individual module failures are serviced without replacing the entire mainframe. Optical port cleaning resolves many apparent measurement faults before mechanical repair is needed.
JDS Uniphase 4126LM price
This JDS Uniphase 4126LM is listed at $1,450. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase 4126LM calibration cost
NIST-traceable calibration for the JDS Uniphase 4126LM is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers distance accuracy verified against a calibrated fiber length reference, event loss measurement accuracy at splice and connector events, dead zone (event and attenuation) at rated pulse width, dynamic range verification at 1310 nm and 1550 nm, backscatter coefficient calibration, and return loss measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →