Fluke 5080A High Compliance Multi-Product Calibrator

The Fluke 5080A Multi-Product Calibrator calibrates a wide range of analog and digital multimeters, clamp meters, panel meters, electronic thermometers, chart recorders, and more. It sources dc voltage, ac voltage, dc current, ac current, resistance, capacitance, thermocouples, and RTDs.

Model
Fluke 5080A
Calibration
Available on request
Price
$22,480
Status
In stock
RFQ ref
5080A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 5080A High Compliance Multi-Product Calibrator delivers precision calibration across voltage, current, resistance, and power measurements. This versatile instrument sources and measures DC/AC signals with high compliance output and integrated protection circuitry, protecting against damaging input levels. Its broad output range and accuracy specifications make it suitable for calibrating analog meters, digital multimeters (3.5 and 4.5 digit), panel meters, watt meters, clamp meters, and oscilloscopes to 200 MHz.


Technical Specifications

DC Voltage: 0 to ±1020 V; ±0.025% of setting accuracy (1 year) AC Voltage: 1 mV to 1020 V (45 Hz to 1 kHz, sine); ±0.1% of setting accuracy DC Current: 0 to ±20.5 A; ±0.025% of setting accuracy; maximum compliance voltage to 50 V AC Current: 29 mA to 20.5 A (45 Hz to 1 kHz, sine); ±0.1% of setting accuracy; 44 V maximum compliance Resistance: 0 to 190 MΩ (19 values in x1 and x1.9 steps); ±0.025% of setting accuracy DC Power: 10.9 mW to 20.5 kW; ±0.11% of setting accuracy AC Power: 10.9 mW to 20.5 kW (45–65 Hz, PF=1); ±0.36% of setting accuracy Phase: 0 to ±179.99° (45 Hz to 1 kHz); ±0.25° of setting accuracy Frequency: 45 Hz to 1 kHz; ±50 ppm of setting accuracy

Key Features



  • High compliance voltage design for reliable source and measure operations

  • Selectable output burden: up to 800 mA for voltage, scaled by range

  • Optional megohm meter calibration sources resistances to 18 GΩ

  • Oscilloscope calibration option validates dynamic response, bandwidth, timing, and triggering to 200 MHz

  • Clamp meter calibration via 9100-200 10/50 turn coil or 5500A/COIL 50-turn accessory

  • Paperless results recording through versatile software applications


Typical Applications



  • Analog and digital meter calibration

  • Multimeter verification and certification

  • Power meter and watt meter calibration

  • High-impedance instrument validation

  • Field oscilloscope maintenance


Compatibility & Integration Available models include the 5080A base unit, 5080A/MEG (megohm option), 5080A/SC (oscilloscope calibration), and 5080A/SC/MEG (combined options). Existing units accept upgrades to expand measurement capabilities.

Specifications

ParameterValue
Frequency Range45 Hz to 1 kHz | Voltage / Current Range: 0 to ±1020 V DC, 1 mV to 1020 V AC

Fluke 5080A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 5080A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 5080A price

This Fluke 5080A is listed at $22,480. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 5080A calibration cost

NIST-traceable calibration for the Fluke 5080A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents