Fluke 715 – Volt/mA Loop Calibrator

Fluke Multifunction Calibrators. Current: 0–20 mA and 4–20 mA at 0.01% to 0.015% accurac, Voltage: 0–100 mV, Resolution: 0.01 mV to 0.001 V depending on range.

Model
Fluke 715
Calibration
Available on request
Price
$650
Status
In stock
RFQ ref
715
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 715 Volt/mA Loop Calibrator measures and sources voltage and current loop signals for process control and automation applications. Built on Fluke's 80 Series platform, this instrument delivers 0.01% to 0.015% accuracy across multiple ranges with a durable, field-hardened design rated for dust and splash environments. The 715 combines measurement, sourcing, and simulation functions in a single portable package, powered by a single 9V alkaline battery with extended runtime.


Technical Specifications

Measurement Ranges & Accuracy

  • Loop current: 0–20 mA and 4–20 mA at 0.01% to 0.015% accuracy, 0.001 mA resolution

  • Voltage: 0–100 mV, 0–200 mV, 0–10 V, 0–20 V, 0–25 V at 0.01% to 0.015% accuracy

  • Voltage resolution: 0.01 mV to 0.001 V depending on range

  • Process signal measurement from PLCs and transmitters Sourcing and Simulation

  • Loop current source: 0–24 mA and 4–20 mA at 0.001 mA resolution, 0.01% to 0.015% accuracy

  • Output modes: Source and Simulate with step and linear ramp functions

  • Voltage source: 0–100 mV, 0–200 mV, 0–10 V, 0–20 V ranges at 0.01% to 0.015% accuracy

  • Configurable zero and span settings Loop Power Supply

  • 24 V DC output at ±10% accuracy

  • Drive capability: 20 mA into 1000 Ω (battery >6.8 V); 700 Ω (battery 5.8–6.8 V)

  • Simultaneous current measurement supported Display & Interface

  • 5-digit LCD

  • Push-button control

  • Dimensions: 187 × 87 × 32 mm (7.35 × 3.41 × 1.25 in); with holster: 201 × 98 × 52 mm

  • Weight: 330 g (12.3 oz) Environmental & Safety

  • Operating temperature: −10°C to 55°C

  • Operating humidity: 95% at 30°C, decreasing to 35% at 55°C

  • 1-meter drop tested; vibration rated to 2 g, 5–500 Hz

  • CSA C22.2 No. 1010.1:1992 and ANSI/ISA S82 certified

  • Maximum voltage: 30 V

  • EMI tolerant


Key Features



  • Single 9V alkaline battery (ANSI/NEDA 1604A or IEC 6LR619V) with extended life

  • EMI-tolerant design with dust and splash resistance

  • Includes protective holster, test leads, alligator clips, and NIST traceable calibration report


Typical Applications Loop signal verification and troubleshooting in process control systems, transmitter commissioning, and automation circuit validation.


Compatibility & Integration Measures voltage output signals from programmable logic controllers and industrial transmitters. 24 V loop power supply enables field troubleshooting of 4–20 mA instrumentation loops.

Specifications

ParameterValue
Voltage / Current Range0-10 V, 0-100 mV, 0-20 V, 0-200 mV, 0-24 mA

Fluke 715 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 715. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Fluke 715 price

This Fluke 715 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 715 calibration cost

NIST-traceable calibration for the Fluke 715 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents