The Agilent/Keysight 5348A is a portable microwave counter and power meter that combines frequency measurement and power analysis into a single instrument. It covers frequencies from 50 MHz to 26.5 GHz on the primary microwave input, with a secondary input extending down to 10 Hz. The unit delivers measurement resolution selectable from 1 Hz to 1 MHz, tracking speeds up to 1 GHz/sec, and acquisition times under 125 ms.
Power measurement capability spans –70 dBm to +20 dBm with 50 dB dynamic range in 10 dB steps and 0.01 dB resolution in logarithmic mode. Input impedance is 50 ohm on the microwave channel with a maximum safe input of +7 dBm and damage levels reaching +39 dBm at 500 MHz–6 GHz. The ruggedized form factor, five-function key interface, and optional internal battery support field installation, maintenance of microwave links, component testing, and RF measurement tasks.
Sensitivity varies by frequency band: –32 dBm typical at 500 MHz–12.4 GHz, –27 dBm at 12.4–20.0 GHz, and –20 dBm at 20.0–26.5 GHz. Automatic amplitude discrimination isolates the dominant signal when it exceeds nearby signals by 6 dB or more within 500 MHz, or by 20 dB above competing signals in the 500 MHz–26.5 GHz band.
Technical Specifications
- Frequency Counter
Input 1: 50 MHz to 26.5 GHz (CW)
Frequency Counter
Input 2: 10 Hz to 525 MHz
- Resolution: 1 Hz to 1 MHz (selectable), or 1 Hz / 10 kHz
- Tracking Speed: 1 MHz/sec (1 Hz resolution); 1 GHz/sec (10 kHz resolution)
- Acquisition Time: <125 ms at 1 Hz; <60 ms at 10 kHz
- Power Range: –70 dBm to +20 dBm (100 pW to 100 mW); –70 dBm to +44 dBm with specified sensors
- Power Dynamic Range: 50 dB in 10 dB steps
- Power Resolution: 0.01 dB (logarithmic) or 0.1% of full scale (linear)
- Power Accuracy: ±0.02 dB or ±5%
- Input 1 Impedance: 50 ohm
- Input 2 Impedance: 1 Mohm nominal with <70 pF shunt (10 Hz–80 MHz); 50 ohm nominal (10 MHz–525 MHz)
- Maximum Input Level: +7 dBm
- Damage Level (Input 1): +39 dBm at 500 MHz–6 GHz; +36 dBm at 6–18 GHz; +34.8 dBm at 18–26.5 GHz
Key Features
- Dual input configuration for microwave and low-frequency measurements
- Sensitivity ranges from –35 dBm typical (500 MHz–12.4 GHz) to –27 dBm typical (20.0–26.5 GHz)
- Maximum deviation limits: 20 MHz p-p automatic mode; 60 MHz p-p manual mode (HP-IB)
- Maximum FM rate: 10 MHz
- Automatic filter selection for dynamic range optimization
- Digital zero set: ±5% of full scale on most sensitive range
Typical Applications
- Microwave link installation and field maintenance
- RF component characterization and testing
- General-purpose RF and microwave measurements
Compatibility & Integration
- HP-IB interface support for remote control and manual mode configuration
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 Hz to 26.5 GHz (Input 1) |
| 10 Hz to 525 MHz (Input 2) | Power Range (dBm) | '-70 dBm to +20 dBm | Voltage / Current Range: Input 2 damage level: 250 V (DC + AC peak) at DC - 5 kHz |
Agilent / Keysight 5348A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 5348A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight 5348A price
This Agilent / Keysight 5348A is listed at $2,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 5348A calibration cost
NIST-traceable calibration for the Agilent / Keysight 5348A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →