Aeroflex / Tektronix / CDS 53A-307 Relay Driver Card
Aeroflex / Tektronix / CDS Embedded Test Systems. Voltage / Current Range: 0.85 A typical (peak); external relay switching 1 V DC to 50 V DC @ 100 mA per output, 4.75 V DC to 5.25 V DC @ 0.80 A typical (quiescent).
- Model
- Aeroflex / Tektronix / CDS 53A-307
- Calibration
- Available on request
- Price
- $1,599
- Status
- In stock
- RFQ ref
- 53A-307
This unit
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0.85 A typical (peak) |
Aeroflex / Tektronix / CDS 53A-307 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Aeroflex / Tektronix / CDS 53A-307. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Aeroflex / Tektronix / CDS 53A-307 faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.
Aeroflex / Tektronix / CDS 53A-307 price
This Aeroflex / Tektronix / CDS 53A-307 is listed at $1,599. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Aeroflex / Tektronix / CDS 53A-307 calibration cost
NIST-traceable calibration for the Aeroflex / Tektronix / CDS 53A-307 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →