Anritsu 54169A

The Anritsu 54169A is a test set designed for use with Anritsu network analyzers. It facilitates accurate S-parameter measurements of active devices. This test set enhances the capability of network analyzers for comprehensive device characterization.

Model
Anritsu 54169A
Calibration
Available on request
Price
$7,500
Status
In stock
RFQ ref
54169A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 54169A is a scalar network analyzer purpose-built for characterizing active devices including amplifiers and filters across 10 MHz to 40 GHz. The instrument combines an integral signal source with dual receiver channels, delivering 71 dB dynamic range and crystal-based frequency stability at 0.00001% accuracy. Two independent receiver channels enable simultaneous measurements of transmission and reflection parameters with the analyzer's 50 Ω output impedance. Maximum input handling reaches 16 dBm, supporting both bench and production test environments.

Technical Specifications

Frequency Range: 10 MHz to 40 GHz

Source Frequency Resolution: 100 kHz

Source Frequency Accuracy: 0.00001%

Output Impedance: 50 Ω

Receiver Channels: 2

Dynamic Range: 71 dB (minimum and maximum)

Maximum Input Level: 16 dBm

Reference Source: Crystal-based

Data Storage: Floppy disk drive with 13 test pattern capacity; NOVRAM backup included

Programmability: GPIB

Form Factor: Benchtop

Key Features

Transmission gain/loss measurements with fast, accurate execution

Group delay and relative group delay characterization (optional software)

Return loss and SWR measurements with high directivity autotester capability

Distance-to-fault measurements for field testing (optional software)

Low source harmonics and precision return loss for enhanced measurement confidence

Built-in automation with fast recall mode for rapid test procedure sequencing

Sophisticated limit line controls with automated bandwidth search functions

Power measurement capability across the 10 MHz–40 GHz band

Typical Applications

Production testing and characterization of active RF devices

Filter and amplifier validation across microwave frequencies

Field troubleshooting and cable fault localization

Transmission line and component SWR assessment

Compatibility & Integration The 54169A pairs with Anritsu 5607V50 RF detectors and accepts external 60 dB step attenuators (Hewlett Packard 8495B/8495D, 0–26.5 GHz) for systems without internal attenuation. Precision adapters convert RF output to N female connectors for test point integration.

Specifications

ParameterValue
Frequency Range10 MHz to 40 GHz | Power Range (dBm): '-16 dBm (maximum input)

Anritsu 54169A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 54169A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu 54169A price

This Anritsu 54169A is listed at $7,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 54169A calibration cost

NIST-traceable calibration for the Anritsu 54169A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents