HP / Agilent 54600B 2 Channel 100 MHz Oscilloscope
The HP/Agilent 54600B is a dual-channel, 100 MHz analog oscilloscope. It features a bright CRT display, intuitive controls, and versatile triggering options. Ideal for electronics testing, troubleshooting, and education, it offers reliable performance and accurate waveform analysis.
- Model
- HP / Agilent 54600B
- Calibration
- Available on request
- Price
- $320
- Status
- In stock
- RFQ ref
- 54600B
This unit
The HP/Agilent 54600B is a dual-channel, 100 MHz analog oscilloscope built for production testing, field service, and educational applications. This instrument delivers 20 MSa/s maximum sample rate with 4,000-point record length and real-time vector display capability. Channel sensitivity spans 2 mV/div to 5 V/div with ±2% DC gain accuracy. The 5 ns/div to 5 s/div timebase supports horizontal accuracy of ±0.01% and 100 ps resolution. Peak detect captures glitches as narrow as 50 ns. Four trigger modes
Auto Level, Auto, Normal, and Single - with selectable sources (CH 1, CH 2, Line, External) enable flexible signal capture. Dual cursors with user-configurable thresholds support automatic voltage and time measurements including frequency, period, rise/fall time, and duty cycle. Setup storage preserves up to 16 front-panel configurations. Negative time viewing, waveform storage, and automatic setup accelerate troubleshooting workflows. The instrument weighs under 15 pounds in a compact, lightweight form factor.
Technical Specifications Vertical System
Channels: 2
Sensitivity: 2 mV/div to 5 V/div
Input impedance: 1 MΩ (approx. 13 pF)
Maximum input: 400 V DC + peak AC
DC gain accuracy: ±2%
CMRR: Approx. 20 dB at 50 MHz
Coupling: DC, AC, or Ground
Bandwidth limit: Approx. 20 MHz
Dynamic range: ±8 div from center Horizontal System
Timebase range: 5 ns/div to 5 s/div
Horizontal accuracy: ±0.01%
Horizontal resolution: 100 ps
Delayed sweep: Available Acquisition
Sample rate: 20 MSa/s (max)
Record length: 4,000 points (max)
Display update rate: Up to 1.5 million points/sec
Single-shot bandwidth: DC to 2 MHz
Peak detect: 50 ns minimum glitch capture Trigger System
Sources: CH 1, CH 2, Line, External
Modes: Auto Level, Auto, Normal, Single
Sensitivity: 0.35 div or 3.5 mV (DC to 25 MHz)
External coupling: DC
Adjustable holdoff
Key Features
Vector mode with brightness modulation for waveform visualization
Automatic measurements: voltage (Vamp, Vavg, Vrms, Vpp), time (delay, duty cycle, frequency, period, rise/fall time)
Dual-cursor measurements with vertical accuracy ±1.2% of full scale (single) or ±0.4% of full scale (dual)
Stores and recalls 16 independent front-panel setups
Negative time capture for pre-trigger event analysis
CRT display with intuitive front-panel controls
Typical Applications
Production test and manufacturing validation
Field service diagnostics
Educational laboratory instruction
Waveform analysis and signal troubleshooting
Compatibility & Integration Standard AC power operation. Two-channel architecture supports simultaneous dual-signal measurement with independent vertical gain and coupling selection per channel.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 100 MHz | Voltage / Current Range: 0-400 V DC + peak AC input |
HP / Agilent 54600B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 54600B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 54600B price
This HP / Agilent 54600B is listed at $320.2. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 54600B calibration cost
NIST-traceable calibration for the HP / Agilent 54600B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →